The hydrogen/deuterium (H/D) exchange process in fused-silica capillary columns was extensively studied using two old and two new columns. The compounds selected for this study were mixtures of phenol and monodeuteriophenol with different compositions. The factors controlling and influencing this phenomenon, such as heating rate and flow-rate variation as a function of residence time on the internal column-surface, were also evaluated. Temperature programming and isothermal analysis were performed for comparison. All studied factors proved that old fused-silica capillary columns exhibit sufficient activity to affect H/D exchange of monodeuteriophenol compounds, but the degree of exchange depends mainly on the position of ring deuteration. However, new columns were found to be less reactive toward H/D exchange and the percentage of exchange may be considered to be within the experimental error.
机译:使用两个旧的色谱柱和两个新的色谱柱对熔融石英毛细管柱中的氢/氘(H / D)交换过程进行了广泛的研究。选择用于该研究的化合物是具有不同组成的苯酚和单氘代苯酚的混合物。还评估了控制和影响此现象的因素,例如加热速率和流速随柱内表面停留时间的变化。进行温度编程和等温分析以进行比较。所有研究的因素都证明,旧的熔融硅胶毛细管柱具有足够的活性来影响单氘代苯酚化合物的H / D交换,但交换程度主要取决于环氘的位置。但是,发现新色谱柱对H / D交换的反应性较小,并且交换百分比可被认为在实验误差范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号