首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >DETERMINATION OF ALENDRONATE SODIUM BY ION CHROMATOGRAPHY WITH REFRACTIVE INDEX DETECTION
【24h】

DETERMINATION OF ALENDRONATE SODIUM BY ION CHROMATOGRAPHY WITH REFRACTIVE INDEX DETECTION

机译:折光指数离子色谱法测定阿魏酸钠。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Refractive index (RI) detection is applied to the ion chromatographic OC) determination of alendronate sodium, an important drug for the treatment of bone diseases, using a Waters IC-Pak HR anion-exchange column with dilute nitric acid (6 mM) as the mobile phase. The method is validated and demonstrated to be accurate, precise, specific and robust. It is a good, alternative method for routine assay vs. the IC-indirect UV method. The detection limit (4 . 10(-4) mg/ml) is comparable to or better than that of the IC-indirect UV detection (1 . 10(-3) mg/ml). The mechanism of the IC separation was explored by the application of the Regnier retention model and van't Hoff analysis.