首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Hydrophilic interaction liquid chromatography - charged aerosol detection as a straightforward solution for simultaneous analysis of ascorbic acid and dehydroascorbic acid
【24h】

Hydrophilic interaction liquid chromatography - charged aerosol detection as a straightforward solution for simultaneous analysis of ascorbic acid and dehydroascorbic acid

机译:亲水相互作用液相色谱法-带电气溶胶检测是同时分析抗坏血酸和脱氢抗坏血酸的直接解决方案

获取原文
获取原文并翻译 | 示例
           

摘要

Ascorbic acid (AA) and dehydroascorbic acid (DHA) are small polar molecules difficult to be retained in conventional chromatographic RP systems. Hydrophilic interaction liquid chromatography (HILIC) using Obelisk R (100 x 3.2 mm, 5 μm, Sielc) analytical column and isocratic elution by ammonium acetate buffer pH 4.2 was found to be successful at this task, while other tested HILIC columns - Obelisk N (100 x 3.2 mm, 5_m, Sielc) and Luna HILIC (100 x 3.0 mm, 3_m, Phenomenex) were unsuccessful for the purposes of analysis. Charged aerosol detection (CAD) has recently become a new alternative universal detection sys_tem in HPLC, and was extremely convenient for the simultaneous analysis of AA and DHA without the need of subtraction approach and oxidation/reduction step. CAD response was found linear in defined range in spite of the fact that CAD is designated as non-linear detection method. A simple and fast HILIC-CAD method was applied for the analysis of pharmaceutical preparations containing AA. Method validation was performed including parameters of precision, accuracy, linearity, limit of detection and limit of quan_titation (LOQ). The method was fast, accurate and precise for both detectors with LOQ_(AA) 5 μg/ml for UV detection and 10 _g/ml for CAD, respectively. DHA was detected only by CAD within tested concentration range with LOQ_(DHA) 1μg/ml.
机译:抗坏血酸(AA)和脱氢抗坏血酸(DHA)是小的极性分子,难以保留在常规色谱RP系统中。发现使用Obelisk R(100 x 3.2 mm,5μm,Sielc)分析柱进行亲水相互作用液相色谱(HILIC)并通过乙酸铵缓冲液pH 4.2等度洗脱可成功完成此任务,而其他测试的HILIC柱-Obelisk N( 100 x 3.2毫米(5毫米,Sielc,Sielc)和Luna HILIC(100 x 3.0毫米,3毫米,Phenomenex)未成功进行分析。带电气溶胶检测(CAD)最近已成为HPLC中一种新的替代通用检测系统,对于同时分析AA和DHA极为方便,而无需使用减法和氧化/还原步骤。尽管CAD被指定为非线性检测方法,但仍在一定范围内发现了CAD响应线性。一种简单快速的HILIC-CAD方法用于分析含有AA的药物制剂。进行了方法验证,包括精度,准确性,线性,检测限和定量限(LOQ)参数。对于两种检测器,该方法都是快速,准确和精确的,分别用于UV检测的LOQ_(AA)5μg/ ml和用于CAD的LOQ_(AA)10_g / ml。仅在LOQ_(DHA)1μg/ ml的测试浓度范围内通过CAD检测到DHA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号