BACKGROUND: Use of communication devices in the hospital environment remains controversial. Electromagnetic interference (EMI) can affect different medical devices. Potential sources for EMI on ECG machines were systematically tested. HYPOTHESIS: Communication devices produce EMI on ECG machines. EMI impairs ECG interpretation. METHODS: The communication devices tested were: a global system for mobile communication (GSM) receiver, a code division multiple access (CDMA) receiver, an analog phone, a wireless local area network, and an alpha-numeric pager. EMI was tested on 3 ECG machines: MAC 5000, MAC 1200, and ELI 100. The devices were tested at 2 and 1 meter, 50, 25, and 0 cm from the acquisition module. The ECGs were presented to a heterogeneous group of clinical providers, (medical students, residents, nurses, industry representatives from cardiac devices companies, and attending cardiologists) to evaluate the impact of EMI on ECG interpretation skills. RESULTS: EMI was detected on the MAC 5000 ECG machine when activated GSM, CDMA, and analog phones were placed on top of the acquisition module. No EMI was seen on the other ECG machines or when phones were at a longer distance or deactivated. EMI was incorrectly diagnosed in 18% of the cases. EMI was confused most frequently with atrial fibrillation or flutter (52%), ventricular arrhythmias (22%), and pacemaker dysfunction (26%). Medical students (p < 0.003) and non-cardiology residents (p = 0.05) demonstrated significantly worse performance on EMI interpretation. CONCLUSIONS: Digital and analog phones produce EMI on modern ECG machines when activated in direct contact to the acquisition module. EMI impairs ECG interpretation.
机译:背景:在医院环境中使用通信设备仍然存在争议。电磁干扰(EMI)会影响不同的医疗设备。系统测试了ECG机器上EMI的潜在来源。假设:通信设备在ECG机器上产生EMI。 EMI损害ECG解释。方法:测试的通信设备为:全球移动通信(GSM)接收器系统,码分多址(CDMA)接收器,模拟电话,无线局域网和字母数字寻呼机。 EMI在3台ECG机器上进行了测试:MAC 5000,MAC 1200和ELI100。这些设备在距采集模块2米和1米,50米,25米和0厘米处进行了测试。将ECG呈现给不同种类的临床提供者(医学生,居民,护士,心脏设备公司的行业代表以及就诊的心脏病专家),以评估EMI对ECG解释技能的影响。结果:当将激活的GSM,CDMA和模拟电话放在采集模块顶部时,在MAC 5000 ECG机器上检测到EMI。在其他ECG机器上,或者在距离较远的手机或停用手机时,都没有看到EMI。在18%的病例中未正确诊断EMI。 EMI最常与房颤或扑动(52%),室性心律不齐(22%)和起搏器功能障碍(26%)混淆。医学生(p <0.003)和非心脏病学居民(p = 0.05)在EMI解释方面表现出明显较差的表现。结论:数字和模拟电话在直接与采集模块接触时被激活,会在现代ECG机器上产生EMI。 EMI损害ECG解释。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号