首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Retention controlling and peak shape simulation in anion chromatography using multiple equilibrium model and stochastic theory
【24h】

Retention controlling and peak shape simulation in anion chromatography using multiple equilibrium model and stochastic theory

机译:基于多重平衡模型和随机理论的阴离子色谱保留率控制和峰形模拟

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The stochastic theory of chromatography and an equilibrium based approach were used for the prediction of peak shape and retention data of anions. This attempt incorporating the potential advantages of two different chromatographic phenomena for analytical purposes. It is an integrated method to estimate kinetic and thermodynamic properties for the same chromatographic run of ions. The stochastic parameters of eluted anions, such as the residence time of the molecule on the surface of the stationary phase, and the average number of adsorption steps were determined on the basis of a retention database of organic and inorganic anions (formate, chloride, bromide, nitrate, sulphate, oxalate, phosphate) obtained by using carbonate/bicarbonate eluent system at different pHs (9-11) and concentrations (7-13 mM). In the investigated IC system the residence times are much higher and the average number of sorption steps is somewhat smaller than in RP-HPLC. The simultaneous application of the stochastic and the multispecies eluent/analyte model was utilized to peak shape simulation and the retention controlling of various anions under elution conditions of practical importance. The similarities between the measured and the calculated chromatograms indicates the predictive and simulation power of the combined application of the stochastic theory and the multiple species eluent/analyte retention model. (C) 2007 Elsevier B.V. All rights reserved.
机译:色谱的随机理论和基于平衡的方法用于预测阴离子的峰形和保留数据。出于分析目的,这种尝试结合了两种不同色谱现象的潜在优势。它是一种估算相同离子色谱运行动力学和热力学性质的综合方法。根据有机和无机阴离子(甲酸根,氯离子,溴离子)的保留数据库,确定洗脱的阴离子的随机参数,例如分子在固定相表面上的停留时间以及平均吸附步骤数。碳酸盐/碳酸氢盐洗脱液系统在不同的pH值(9-11)和浓度(7-13 mM)下获得的硝酸盐,硝酸盐,硫酸盐,草酸盐,磷酸盐)。在研究的IC系统中,与RP-HPLC相比,其停留时间要高得多,平均吸附步骤数要少一些。同时使用随机和多物种洗脱液/分析物模型进行峰形模拟和在实际重要的洗脱条件下控制各种阴离子的保留。测量色谱图和计算色谱图之间的相似性表明,随机理论和多种类洗脱液/分析物保留模型结合应用的预测能力和模拟能力。 (C)2007 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信