首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untreated environmental water samples
【24h】

In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untreated environmental water samples

机译:管内固相微萃取-毛细管液相色谱法作为未经处理的环境水样品中有机磷农药筛选分析的解决方案

获取原文
获取原文并翻译 | 示例

摘要

This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 mu m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 mu m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysiloxane. The proposed methodology provided limits of detections (LODs) for the tested organophosphorus pesticides in the 0.1-10 mu g/L range, whereas the direct injection of the samples onto the capillary LC system provided LODs in the 50-1000 mu g/L range. The sensitivity of the proposed in-tube SPME-capillary LC method is adequate to monitorize the analyte levels in drinking water. Several triazines, polycyclic aromatic hydrocarbons (PAHs), nonylphenol, organochloride pesticides or polybrominated diphenyl ethers (PBDEs) have been evaluated as possible interferents. The reliability of the described method is demonstrated by analysing different real water samples. (c) 2006 Elsevier B.V. All rights reserved.
机译:本文介绍了一种选择性筛选水中有机磷农药的方法。在开放式毛细管柱中的管内固相微萃取(SPME)与带有UV检测的毛细管液相色谱(LC)结合已用于对同一组件中的分析物进行预浓缩,分离和检测。对于管内SPME,已测试并比较了两个长度相同,内径和涂层厚度不同的毛细管柱,分别为30 cm x 0.25 mm内径,0.25μm厚度的涂层柱和30 cm x 0.1 mm内径,0.1微米的涂层厚度柱。在两个塔中,涂层均为95%的二甲基聚硅氧烷(PDMS)-5%的二苯基聚硅氧烷。所提出的方法为所测试的有机磷农药提供了0.1-10μg / L范围内的检出限(LOD),而将样品直接注入毛细管液相色谱系统则提供了50-1000μg / L范围内的LOD。 。拟议的管内SPME毛细管液相色谱法的灵敏度足以监测饮用水中的分析物含量。已评估了几种三嗪,多环芳烃(PAH),壬基酚,有机氯化物农药或多溴联苯醚(PBDE)作为可能的干扰物。通过分析不同的真实水样可以证明所描述方法的可靠性。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号