...
首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Determination of ink photoinitiators in packaged beverages by gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry
【24h】

Determination of ink photoinitiators in packaged beverages by gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry

机译:气相色谱-质谱和液相色谱-质谱法测定包装饮料中的油墨光引发剂

获取原文
获取原文并翻译 | 示例
           

摘要

A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimetliylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-l-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 mu g l(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 mu g l(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217 mu g l(-1). Its presence was confirmed by an LC/Atmospheric-Pressure Photolonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 mu g l(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 mu g l(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages. (c) 2008 Elsevier B.V. All rights reserved.
机译:开发了一种使用气相色谱-质谱(GC / MS)和液相色谱-质谱(LC / MS)技术的新分析方法,用于测定包装食品中五个油墨光引发剂残留物:2-异丙基噻吨酮(ITX) ,二苯甲酮,2-乙基己基-4-二甲基氨基苯甲酸酯(EHDAB),1-羟基环己基-1-苯基酮(IRGACURE 184)和4-二甲基氨基苯甲酸乙酯(EDAB)。使用正己烷和二氯甲烷分别从选定的饮料(牛奶,果汁和葡萄酒)和相关包装中提取样品,在固相萃取(SPE)硅胶柱上纯化,然后在GC / MS和LC / MS中进行分析多发性硬化症。用光引发剂的标准混合物将浓度为4和10μggl(-1)的饮料样品加标所获得的回收率范围为42-108%(牛奶),50-84%(葡萄酒)和48 -109%(果汁)。在所有情况下,均以相关值的百分比(小于19%)评估该方法的可重复性。使用GC / MS获得的最低检测限(LOD)和定量限(LOQ)分别在0.2-1和1-5μg l(-1)范围内。该方法用于分析四十种包装食品饮料(牛奶,果汁和葡萄酒样品)。最显着的污染是二苯甲酮,在所有样品中发现的浓度范围为5-217μg l(-1)。通过LC /大气压光致电离(APPI)/ MS / MS分析确认了其存在。在40种饮料中的11种中发现了光引发剂(EHDAB),其浓度范围为0.13-0.8μg l(-1)。不太重要的是ITX污染,在四十个样本中的三个样本中发现的浓度范围为0.2-0.24μg l(-1)。这项工作提出了一种新方法,用于分析多耦合纸盒包装和所含食品饮料中的油墨光引发剂残留。 (c)2008 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号