首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Development and optimization of an analytical method for the determination of Sudan dyes in hot chilli pepper by high-performance liquid chromatography with on-line electrogenerated BrO--luminol chemiluminescence detection
【24h】

Development and optimization of an analytical method for the determination of Sudan dyes in hot chilli pepper by high-performance liquid chromatography with on-line electrogenerated BrO--luminol chemiluminescence detection

机译:高效液相色谱-在线电生BrO-鲁米诺化学发光检测法测定辣椒中苏丹红的分析方法的开发与优化

获取原文
获取原文并翻译 | 示例
       

摘要

The determination of four Sudan dyes by means of high-performance liquid chromatography (HPLC) with chemiluminescence (CL) detection was proposed. The method was based on the enhancement effect of Sudan dyes on the chemiluminescence reaction between luminol and BrO-, which was on-line electrogenerated by constant current electrolysis. The separation was carried out on Nucleosil RP-C-18 column (250 mm x 4.6 mm i.d., 5 mu m, pore size, 100 angstrom) at 35 degrees C. The mobile phase consisted of a V (methanol): V (0.2% aqueous formic acid) = 90: 10 solution. At a flow-rate of 1.0 ml min(-1), the total run time was 25 min. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. For the four Sudan dyes, the limits of detection (LOD) at a signal-to-noise of 3 ranged from 4 to 8 mu g kg(-1) and the limits of quantification (LOQ) at a signal-to-noise of 10 ranged from 13 to 27 mu g kg(-1). The relative standard deviations (RSD) of intra-and inter-day precision were below 4.4%. The average recoveries for all four Sudan dyes (spiked at the levels of 1.0 and 1.5 mu g kg(-1)) in chilli tomato sauce and hot chilli pepper ranged from 94% to 105%, and the relative standard deviations of the quantitative results were from 2.5 to 4.2%. The proposed method had been successfully applied to the determination of four Sudan dyes in hot chilli products. (c) 2006 Elsevier B.V. All rights reserved.
机译:提出了采用化学发光(CL)检测的高效液相色谱法(HPLC)测定四种苏丹红的方法。该方法基于苏丹染料对鲁米诺与BrO-之间化学发光反应的增强作用,后者是通过恒流电解在线产生的。分离是在35摄氏度的Nucleosil RP-C-18色谱柱(250 mm x 4.6 mm内径,5μm,孔径,100埃)上进行的。流动相由V(甲醇):V(0.2)组成。 %的甲酸水溶液)= 90:10溶液。在1.0 ml min(-1)的流速下,总运行时间为25分钟。系统地研究了几个参数对HPLC分离度和CL排放的影响。对于四种苏丹染料,信噪比为3时的检出限(LOD)为4至8微克kg(-1),而信噪比为3时的定量限(LOQ)为10介于13到27微克kg(-1)之间。日内和日间精度的相对标准偏差(RSD)低于4.4%。辣椒番茄酱和辣椒中四种苏丹红染料的平均回收率(分别为1.0和1.5μg kg(-1))在94%至105%之间,定量结果的相对标准偏差从2.5%降至4.2%。所提出的方法已成功地应用于辣椒产品中四种苏丹红的测定。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号