The aim of this study was to identify and quantify an unknown peak in the chromatogram of a very complex mixture, a straight oil metalworking fluid (MWF). The fraction that permeated through a thin nitrile polymer membrane had less mineral oil background than the original MWF did at the retention time of the unknown peak, thus facilitating identification by total ion current (TIC) gas chromatography-mass spectrometry (GC-MS). The peak proved to be di-n-octyl disulfide (DOD) through retention time and mass spectral comparisons. Quantitation of DOD was by extracted ion chromatogram analysis of the DOD molecular ion (mass-to-charge ratio (m/z) 290), and of the m/z 71 ion for the internal standard, n-triacontane. Linear models of the area ratio (y) of these two ions versus DOD concentration showed a systematic negative bias at low concentrations, a common occurrence in analysis. The linear model of y(0.8) (from Box-Cox power transformation) versus DOD concentration showed negligible bias from the lowest measured standard of 1.51 mg/L to the highest concentration tested at 75.5 mg/L. The intercept did not differ statistically from zero. The concentration of DOD in the MWF was then calculated to be 0.398 +/- 0.034% (w/w) by the internal standard method, and 0.387 +/- 0.036% (w/w) by the method of standard additions. These two results were not significantly different at p < 0.05. The Box-Cox transformation is therefore recommended when the data for standards are non-linear. (c) 2005 Elsevier B.V. All fights reserved.
机译:这项研究的目的是鉴定和定量非常复杂的混合物(纯油金属加工液(MWF))的色谱图中的未知峰。在未知峰的保留时间,渗透穿过丁腈聚合物薄膜的馏分的矿物油背景要比原始MWF少,因此有助于通过总离子流(TIC)气相色谱-质谱(GC-MS)进行鉴定。通过保留时间和质谱比较,该峰证明为二正辛基二硫化物(DOD)。通过对DOD分子离子(质荷比(m / z)290)和内标正三金刚烷的m / z 71离子进行提取离子色谱分析,对DOD进行定量。这两个离子的面积比(y)与DOD浓度的线性模型显示出在低浓度下系统的负偏差,这在分析中很常见。 y(0.8)(来自Box-Cox功率变换)对DOD浓度的线性模型显示,从最低的测量标准物1.51 mg / L到测试的最高浓度75.5 mg / L,偏差可以忽略不计。截距在统计上与零没有差异。然后通过内标法计算出MWF中DOD的浓度为0.398 +/- 0.034%(w / w),通过标准添加法计算为0.387 +/- 0.036%(w / w)。这两个结果在p <0.05时无显着差异。因此,当标准数据为非线性时,建议进行Box-Cox转换。 (c)2005 Elsevier B.V.版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号