首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Application of comprehensive two-dimensional gas chromatography with nitrogen-selective detection for the analysis of fungicide residues in vegetable samples
【24h】

Application of comprehensive two-dimensional gas chromatography with nitrogen-selective detection for the analysis of fungicide residues in vegetable samples

机译:综合二维气相色谱-氮选择性检测技术在蔬菜样品杀菌剂残留分析中的应用

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Comprehensive two-dimensional gas chromatography (GCxGC) with nitrogen-phosphorus detection (NPD) has been investigated for the separation and quantitation of fungicides in vegetable samples. The detector gas flows (H-2, N-2 and air) were adjusted to achieve maximum response of signal whilst minimizing peak width. The comparison of different column sets and selection of the temperature program were carried out with a mixture of nine N-containing standard fungicides, eight of which were chlorinated. The results from GCxGC-NPD and GCxGC with micro electron-capture detection (mu ECD) were compared. External calibrations of fungicides were performed over a concentration range from I to 1000 mu g L-1. The peak area calibration curves generally had regression coefficients of R-2 > 0.9980, however for iprodione which was observed to undergo on-column degradation, an R-2 of 0.990 was found. The limit of detection (LOD) and limit of quantitation (LOQ) were less than about 74 and 246 ng L-1, respectively. The intra-day and inter-day RSD values were measured for solutions of concentration 0.100, 0.500 and 1.50 mg L-1. For the 0.500 mg L-1 solution, intra- and inter-day precision of peak area and peak height for most of the pesticides were about 2% and 8%, respectively. Excellent linearity was observed for these standards, from 0.001 to 25.00 mg L-1. The standard mixture peak positions were identified by using GCxGC with quadrupole mass spectrometry (qMS). To illustrate the potential and the versatility of both GCxGC-NPD and GCxGC-mu ECD, the method was applied to determination of fungicides in a vegetable extract. Decomposition of one fungicide standard (iprodione) during chromatography elation was readily observed in the two-dimensional (2D) GCxGC plot as a diagonal ridge response in the 2D chromatogram between the degrading compound and the decomposition product. (c) 2006 Elsevier B.V. All rights reserved.
机译:已经对具有氮磷检测(NPD)的综合二维气相色谱(GCxGC)进行了蔬菜样品中杀菌剂的分离和定量研究。调节检测器气流(H-2,N-2和空气)以实现信号的最大响应,同时最大程度地减小峰宽。使用九种含氮标准杀菌剂的混合物进行了不同色谱柱组的比较和温度程序的选择,其中八种经过氯化处理。比较了具有微电子捕获检测(mu ECD)的GCxGC-NPD和GCxGC的结果。杀菌剂的外部校准是在I至1000μg L-1的浓度范围内进行的。峰面积校准曲线通常具有R-2> 0.9980的回归系数,但是对于观察到的iprodione柱上降解,发现R-2为0.990。检测限(LOD)和定量限(LOQ)分别小于约74和246 ng L-1。测量浓度为0.100、0.500和1.50 mg L-1的溶液的日内和日间RSD值。对于0.500 mg L-1溶液,大多数农药的峰面积和峰高的日内和日间精度分别约为2%和8%。对于这些标准品,从0.001至25.00 mg L-1观察到了极好的线性。使用GCxGC和四极杆质谱(qMS)鉴定标准混合物的峰位置。为了说明GCxGC-NPD和GCxGC-mu ECD的潜力和多功能性,该方法用于测定蔬菜提取物中的杀菌剂。在二维(2D)GCxGC图中,在降解化合物与分解产物之间的二维色谱图中,对角脊峰响应很容易在二维(2D)GCxGC图中观察到一种杀菌剂标准品(异丙洛酮)的分解。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号