Measurement of serum thyroglobulin (Tg) is a highly specific test in the management of patients with differentiated thyroid cancer (DTC) after surgical treatment. The aim of our study was to evaluate and compare Tg levels in these patients found by radioimmunoassay (RIA) and immunoradiometric assay (IRMA) and to assess the influence of Tg antibodies (TgAbs) on the values obtained for Tg concentration. Both Tg and TgAb were determined postoperatively in the serum of 71 DTC patients using RIA Tg-PEG (INEP) and Tg IRMA (CIS) for Tg, together with TgAb (CIS) for circulating endogenous anti-TgAbs. The obtained concentrations were evaluated statistically. We found a significant difference of Tg concentrations between paired samples from the IRMA and RIA, although the intermethod comparison yielded satisfactory concordance of the two assays (Spearman correlation coefficient -0.792). Positive TgAb was found in 28.2% of the serum samples analyzed. Spearman rank correlation analysis revealed a significant negative relationship between serum TgAb and Tg level measured by IRMA (P=0.02), but not by RIA (P=0.417). On the other hand, our clinical data revealed that 1/18 and 3/18 patients with proven lymph node metastasis had Tg values below the detection limit by RIA and IRMA assay, respectively. Their sera were TgAb positive. We concluded that RIA was less prone to influence of TgAb than IRMA. As the presence of TgAbs may interfere in Tg measurement irrespective of the method selected for determination, this should be considered during the clinical management of these patients.
机译:血清甲状腺球蛋白(Tg)的测量是外科治疗后分化型甲状腺癌(DTC)患者管理中的高度特异性测试。我们研究的目的是评估和比较通过放射免疫测定(RIA)和免疫放射测定(IRMA)发现的这些患者中的Tg水平,并评估Tg抗体(TgAbs)对获得的Tg浓度值的影响。使用RIA Tg-PEG(INEP)和Tg IRMA(CIS)进行Tg以及TgAb(CIS)循环内源性抗TgAbs的测定,在71名DTC患者的血清中确定了Tg和TgAb。对获得的浓度进行统计学评估。我们发现IRMA和RIA配对样品之间的Tg浓度存在显着差异,尽管方法间比较得出两种测定的一致性令人满意(Spearman相关系数-0.792)。在分析的血清样本中有28.2%的TgAb阳性。 Spearman等级相关分析显示,通过IRMA(P = 0.02)而非RIA(P = 0.417)测得的血清TgAb与Tg水平呈显着负相关。另一方面,我们的临床数据显示,已证实淋巴结转移的1/18和3/18患者的Tg值分别低于RIA和IRMA分析的检测极限。他们的血清是TgAb阳性。我们得出的结论是,与IRMA相比,RIA不太容易受到TgAb的影响。由于TgAb的存在可能会干扰Tg的测量,而与选择测定方法无关,因此在这些患者的临床治疗期间应考虑到这一点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号