Background: Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. Methods: We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. Results: We find that all values for creatinine on samples stored at 4°C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. Conclusion: We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer.
机译:背景:由于在Advia 1650上使用了不同的空白进行肌酐测定,因此患者的血清肌酐值往往会发生变化。将分析仪升级到Advia 1800后,肌酐值趋于更可重复。作为检验肌酐值可重复性的质量保证调查的一部分,我们确定了13例患者血清中的系列肌酐值,其初始值在参考范围内或升高(范围在0.58-7.8 mg / dl)。这些值与血清尿素氮(BUN)测定同时测定(范围6.0-84.4 mg / dl),因为这两种分析物一起用于评估肾功能。方法:我们分别使用谷氨酸脱氢酶内衬酶测定系统和Jaffe方法测定BUN和肌酐值。结果:我们发现,在4°C储存的样品中,肌酐的所有值都是可重复的,相应的BUN值也是可重复的,这通过变异系数(CV)的低值显示出来,即肌酐的平均CV为4.55% BUN为2.52%。发现一个肌酐CV相对较高(10.6%)的样品的初始值为1.1 mg / dl,在参考范围内;但是,经反复测定,所获得的水平高达1.5 mg / dl,高于参考范围。该样品的BUN值保持在参考范围内,表明没有肾脏疾病存在。结论:我们得出结论,肌酐和BUN的测定是稳定的,但偶尔在Advia 1800分析仪上会出现虚假的肌酐值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号