首页> 外文期刊>Journal of computer assisted tomography >Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: Impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate
【24h】

Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: Impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate

机译:从118,970台多探测器计算机断层扫描静脉造影剂给药中汲取的经验教训:导管停留时间和量规,导管位置,造影剂给药率以及患者年龄和性别对渗出液体积的影响

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: The aim of this study was to determine the impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate at intravenous contrast-enhanced multidetector computed tomography. METHODS: Incident reports were reviewed for all extravasation events that occurred in adult patients between March 2006 and December 2009 at 2 institutions. Patient age and sex; catheter dwell time, gauge, and location; rate of contrast material administration; and estimated volume of extravasated contrast material were recorded. RESULTS: Three hundred thirty extravasation events were recorded for the 118,970 contrast material administrations (0.3%). Mean volume of extravasated contrast material was statistically significantly less for catheters newly placed in the radiology department, for higher flow rates, for smaller gauge catheters, and for catheters placed in the hand. Mean volume of extravasated contrast material did not vary significantly based on patient age or sex. CONCLUSIONS: The volume of extravasate was likely to be smaller for smaller-gauge catheters in the hand with higher flow rates and for catheters newly placed in the radiology department.
机译:目的:本研究的目的是确定在静脉造影剂增强型多层螺旋CT上,导管停留时间和量规,导管位置,造影剂施用率以及患者年龄和性别对渗出液体积的影响。方法:回顾了2006年3月至2009年12月在2家机构进行的成年患者发生的所有外渗事件的事故报告。患者年龄和性别;导管停留时间,规格和位置;造影剂给药率;并记录外渗造影剂的估计体积。结果:118,970例对比剂给药记录了330次外渗事件(0.3%)。新放置在放射科的导管,较高的流速,较小规格的导管和放置在手中的导管的渗出造影剂的平均体积在统计学上显着减少。根据患者年龄或性别,外渗造影剂的平均体积没有明显变化。结论:对于流速较高的手中较小规格的导管和放射科新放置的导管,渗出液的体积可能较小。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号