首页> 外文期刊>Journal of computer assisted tomography >Assessment of coronary stents using 40-detector row CT: comparison with 16-detector row CT in vitro.
【24h】

Assessment of coronary stents using 40-detector row CT: comparison with 16-detector row CT in vitro.

机译:使用40排螺旋CT评估冠状动脉支架:与16排螺旋CT进行体外比较。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To evaluate the performance of 40-detector row computed tomography (CT) in the assessment of coronary stents in comparison with 16-detector row CT. METHODS: A total of 6 vascular models (3 models without stenosis and 3 with stenosis) using 3 types of stent (Bx-Velocity, Express2, and Driver) with an approximately 3.5-mm inner diameter filled with contrast material (450 Hounsfield units) were scanned with 2 computed tomographic scanners (collimation, 16 x 0.75 and 40 x 0.625 mm). We evaluated the in-stent stenosis visually for the 6 vascular models in 4 orientations (0, 30, 60, and 90 degrees) to the z-axis of the scanner. We evaluated attenuation values of the stent lumen of the 3 patent models in the 4 orientations. The average and standard deviation of the luminal attenuation values were assessed to evaluate the degree of blooming and streak artifacts. RESULTS: The visualization of the stent lumen of the vascular models at 90 degrees was improved using 40-detector row CT. For all the 3 stents, the average luminal attenuations values using 40-detector row CT were significantly lower than those using 16-detector row CT in all orientations. For all the 3 stents, the standard deviations of the luminal computed tomographic attenuation using 40-detector row CT were significantly smaller than those using 16-detector row CT in the 4 orientations to the z-axis except for Express 2 at 0 degrees. CONCLUSIONS: The visualization of coronary stents is improved by the use of 40-detector row CT with reduced blooming and streak artifacts.
机译:目的:与16个探测器行CT相比,评估40个探测器行计算机断层扫描(CT)在评估冠状动脉支架方面的性能。方法:使用6种血管模型(3种无狭窄模型和3种有狭窄模型),使用3种类型的支架(Bx-Velocity,Express2和Driver),其内径约3.5毫米,装有造影剂(450霍恩斯菲尔德单位)用2台计算机断层扫描仪(准直,16 x 0.75和40 x 0.625 mm)扫描。我们在扫描仪z轴的4个方向(0、30、60和90度)上通过视觉评估了6种血管模型的支架内狭窄。我们评估了3个专利模型在4个方向上的支架内腔的衰减值。评估管腔衰减值的平均和标准偏差,以评估起霜和条纹伪影的程度。结果:使用40排行CT可以改善90度血管模型的支架内腔的可视化。对于所有3个支架,在所有方向上使用40个探测器行CT的平均腔内衰减值均显着低于使用16个探测器行CT的腔内衰减值。对于所有3个支架,除了Express 2在0度以外,使用40个探测器行CT的管腔计算机断层摄影术衰减的标准偏差均显着小于使用16个探测器行CT的管腔CT衰减的标准偏差。结论:使用40排行CT减少了晕染和条纹伪影,改善了冠状动脉支架的可视化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号