OBJECTIVE: Evaluation of the image quality of coronary artery stents at various heart rates using Multi Detector Computed Tomography (MDCT). METHODS: Nine different coronary stents were attached to a moving heart phantom and scanned using a 64-MDCT with a rotation time of 330 milliseconds (ms). The heart rate of the phantom was varied between 0 and 115 beats per minute (bpm). Two independent methods were used to investigate image quality. After reconstruction the average Houndsfield Unit (HU) value in the stent lumen was measured in the longitudinal and the cross-sectional plane. The stent images were then presented to two radiologists. The radiologists were asked to rank the images from good to bad based on lumen visibility and overall image quality. A second ranking was obtained using the CT density values. Finally two rankings were compared. RESULTS: Compared to the value for air, the HU-values measured in the lumen increased by 50 to 700 HU. Average slope value in the longitudinal plane was 1.7 +/-0.6 HU/bpm, and the average slope value in the cross-sectional plane was 1.7 +/- 0.8 HU/bpm. This shows increased attenuation with increasing heart rate and thus a negative correlation between image quality and heart rate in both planes for all stents. The ranking acquired from the radiologists resembled the measured results as they also showed a negative correlation between the two variables. Using the results of the CT density measurements an analysis was done on multi-segment reconstruction (MSR). CONCLUSION: A negative correlation between the heart rate and image quality of coronary stents was found by two independent methods. MSR showed no benefit for image quality in this study.
机译:目的:使用多探测器计算机断层扫描(MDCT)评估不同心率下冠状动脉支架的图像质量。方法:将九种不同的冠状动脉支架连接到移动的心脏幻象上,并使用64-MDCT进行扫描,旋转时间为330毫秒(ms)。幻影的心率在每分钟0到115次跳动(bpm)之间变化。使用两种独立的方法来研究图像质量。重建后,在纵向和横截面上测量支架内腔中的平均Houndsfield Unit(HU)值。然后将支架图像呈现给两名放射科医生。要求放射科医生根据流明能见度和整体图像质量从好到坏对图像进行排名。使用CT密度值获得第二等级。最后比较了两个排名。结果:与空气值相比,在管腔中测量的HU值增加了50至700 HU。纵向平面中的平均斜率值为1.7 +/- 0.6HU / bpm,而横截面平面中的平均斜率值为1.7 +/- 0.8HU / bpm。这显示出随心率增加而增加的衰减,因此对于所有支架而言,两个平面上的图像质量和心率之间均呈负相关。从放射科医师获得的排名与测量结果相似,因为它们还显示出两个变量之间的负相关性。使用CT密度测量的结果,对多段重建(MSR)进行了分析。结论:通过两种独立的方法发现心率与冠状动脉支架图像质量之间呈负相关。在这项研究中,MSR对图像质量没有好处。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号