首页> 外文期刊>Journal of computer assisted tomography >Comparison of thallium-201 and gallium-67 imaging in evaluation of head and neck tumors.
【24h】

Comparison of thallium-201 and gallium-67 imaging in evaluation of head and neck tumors.

机译:al 201和镓67成像在头颈部肿瘤评估中的比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: 201Tl imaging was compared with 67Ga imaging in the detection of malignant head and neck tumors. METHOD: Eighteen patients with tumors in the head and neck region underwent both planar and SPECT imaging using 201Tl-chloride and 67Ga-citrate. The detection of primary tumors and lymph node (LN) metastases by visual evaluation was compared between 201Tl and 67Ga imaging. Additionally, quantitative analysis of the SPECT images was performed in eight patients. RESULTS: On visual evaluation, primary tumor uptake was detectable in 100% on the 201Tl SPECT images compared with 44% on the 67Ga SPECT images. The sensitivity, specificity, and accuracy of 201Tl in detecting LN metastases were higher than those of 67Ga SPECT; however, there was no statistical difference between 201Tl and 67Ga. The tumor-to-background ratio was significantly higher on 201Tl SPECT than on 67Ga SPECT. CONCLUSION: This study suggested that 201Tl could be useful in the evaluation of malignant tumors in the head and neck region.
机译:目的:在恶性头颈部肿瘤的检测中,将201T1成像与67Ga成像进行了比较。方法:使用201Tl-氯化物和67Ga-柠檬酸盐对18例头颈部肿瘤进行了平面和SPECT成像。通过视觉评估在201T1和67Ga成像之间比较了对原发肿瘤和淋巴结(LN)转移的检测。此外,对八名患者进行了SPECT图像的定量分析。结果:通过视觉评估,在201T1 SPECT图像上可检测到100%的原发肿瘤摄取,而在67Ga SPECT图像上可检测到44%。 201T1检测LN转移的敏感性,特异性和准确性均高于67Ga SPECT。然而,在201T1和67Ga之间没有统计学差异。 201T1 SPECT上的肿瘤与背景的比率显着高于67Ga SPECT。结论:本研究提示201T1可用于评价头颈部恶性肿瘤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号