Use of the Laryngeal Mask Airway-Aintree Intubating Catheter-fiberoptic bronchoscope technique for difficult intubation

机译:喉罩气管-Aintree插管导管-纤维支气管镜技术用于困难插管的应用

获取原文
获取原文并翻译 | 示例
       

摘要

Study Objective: To determine whether intubation using an Aintree Intubation Catheter (AIC), fiberoptic intubation (FOB), and Laryngeal Mask Airway (LMA) is safe and effective for securing the airway in patients who are difficult to intubate after induction of general anesthesia. Design: Retrospective review of departmental difficult airway database procedures completed between July 2006 and December 2009. Setting: Academic medical center. Measurements and Main Results: During the study period, 128 of 500 patients entered into the difficult airway database underwent the LMA-AIC-FOB technique for intubation. One hundred nineteen (93%) of the 128 patients were successfully intubated by the LMA-AIC-FOB technique, and 9 required an alternate technique. No patient who underwent the LMA-AIC-FOB technique experienced an airway-related mortality or required an emergency surgical airway procedure. Conclusion: The LMA-AIC-FOB technique is safe and effective for patients who are difficult to intubate after induction of anesthesia.
机译:研究目的:确定使用Aintree插管(AIC),光纤插管(FOB)和喉罩气道(LMA)进行插管是否安全有效,以确保在全麻诱导后难以插管的患者的气道。设计:2006年7月至2009年12月间完成的部门困难气道数据库程序的回顾性审查。背景:学术医学中心。测量和主要结果:在研究期间,每500名患者中有128名进入困难气道数据库,接受了LMA-AIC-FOB技术进行插管。 LMA-AIC-FOB技术成功插入了128例患者中的119例(93%),其中9例需要其他技术。没有接受过LMA-AIC-FOB技术的患者经历过气道相关的死亡或需要紧急外科气道手术。结论:LMA-AIC-FOB技术对麻醉后难以插管的患者安全有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号