首页> 外文期刊>Journal of cataract and refractive surgery >Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology.
【24h】

Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology.

机译:使用自适应光学技术在存在4阶和6阶Zernike球差的情况下的主观景深。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To study the impact on the subjective depth of field of 4th-order spherical aberration and its combination with 6th-order spherical aberration and analyze the accuracy of image-quality metrics in predicting the impact. SETTING: Laboratoire Aime Cotton, Centre National de la Recherche Scientifique, Universite Paris-Sud, Orsay, France. DESIGN: Case series. METHODS: Subjective depth of field was defined as the range of defocus at which the target (3 high-contrast letters at 20/50) was perceived acceptable. Depth of field was measured using 0.18 diopter (D) steps in young subjects with the addition of the following spherical aberration values: +/-0.3 mum and +/-0.6 mum 4th-order spherical aberration with 3.0 mm and 6.0 mm pupils and +/-0.3 mum 4th-order spherical aberration with +/-0.1 mum 6th-order spherical aberration for 6.0 mm pupils. RESULTS: The addition of +/-0.3 and +/-0.6 mum 4th-order spherical aberration increased depth of field by 30% and 45%, respectively. The combination of 4th-order spherical aberration and 6th-order spherical aberration of opposite signs increased depth of field more than 4th-order spherical aberration alone (ie, 63%), while the combination of 4th-order spherical aberration and 6th-order spherical aberration of the same signs did not (ie, 24%). Whereas the midpoint of the depth of field could be predicted by image-quality metrics, none was found a good predictor of objectionable depth of field. CONCLUSION: Subjective depth of field increased when 4th-order spherical aberration and 6th-order spherical aberration of opposite signs were added but could not be predicted with image-quality metrics.
机译:目的:研究四阶球差对主观景深的影响及其与六阶球差的结合,并分析图像质量指标在预测影响上的准确性。地点:法国奥赛大学巴黎南分校国家研究中心Aime Cotton实验室。设计:案例系列。方法:主观景深定义为散焦范围,在该范围内,目标(3个高对比度字母在20/50处)被认为可以接受。在年轻受试者中,使用0.18屈光度(D)步长测量了景深,并添加了以下球面像差值:+/- 0.3微米和+/- 0.6微米4阶球面像差,瞳孔分别为3.0 mm和6.0 mm,+ /-0.3的4阶球面像差和+/- 0.1的6.0毫米瞳孔的6阶球面像差。结果:+/- 0.3和+/- 0.6的四阶球面像差分别使景深增加了30%和45%。具有相反符号的四阶球差和六阶球差的组合比单独的四阶球差(即63%)增加了景深,而四阶球差和六阶球差的组合没有相同迹象的像差(即24%)。尽管景深的中点可以通过图像质量指标进行预测,但没有一个可以很好地预测令人讨厌的景深。结论:当添加相反符号的四阶球差和六阶球差时,主观景深会增加,但无法通过图像质量指标进行预测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号