PURPOSE: To assess the rotational stability of a single-piece toric hydrophobic acrylic intraocular lens (IOL) during the first 6 postoperative months. SETTING: Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. DESIGN: Prospective case series. METHOD: Eyes with age-related cataract and corneal astigmatism (1.00 to 3.00 D diopter [D]) were measured by partial coherence interferometry (IOLMaster). Preoperatively, the horizontal axis was marked. Surgical technique included a standardized temporal clear corneal incision, phacoemulsification, and in-the-bag implantation of a toric IOL (AcrySof SN60TT). Rotational stability of the IOL was assessed using retroillumination photographs postoperatively at 1 hour and at 1 and 6 months. Uncorrected (UDVA) and corrected distance visual acuities, residual refractive error, and keratometric and refractive cylinders were measured. RESULTS: The study enrolled 30 eyes (30 patients). The mean absolute IOL rotation was 2.44 degrees +/- 1.84 (SD) at 1 month and 2.66 +/- 1.99 degrees at 6 months. The photographic technique had high reproducibility of axis measurement, with consecutive measurements varying by less than 2.0 degrees. The mean UDVA was 0.16 logMAR (range 0.42 to -0.18 logMAR) at 1 month and 0.20 logMAR (range 0.60 to -0.20 logMAR) at 6 months. The residual refractive cylinder by autorefraction was -0.84 D (range -2.00 to 0.00 D) and -0.80 D (range -1.75 to 0.00 D), respectively. CONCLUSIONS: The acrylic toric IOL was rotationally stable within the first 6 months postoperatively. The photographic and axis analysis method to evaluate stability had high reproducibility and detected small changes in rotation.
机译:目的:评估术后头6个月单片复曲面疏水丙烯酸人工晶状体(IOL)的旋转稳定性。地点:英国伦敦Moorfields眼科医院NHS基金会信托基金。设计:预期案例系列。方法:通过部分相干干涉法(IOLMaster)测量具有年龄相关性白内障和角膜散光(1.00至3.00 D屈光度[D])的眼睛。术前标出横轴。手术技术包括标准化的颞部透明角膜切口,超声乳化术和复曲面IOL(AcrySof SN60TT)的袋内植入。术后1小时,1和6个月使用回照照片评估IOL的旋转稳定性。测量未矫正(UDVA)和矫正的远视力,残余屈光不正以及角膜屈光度和屈光度数。结果:该研究招募了30只眼(30例患者)。 IOL的平均绝对旋转在1个月时为2.44度+/- 1.84度(SD),在6个月时为2.66 +/- 1.99度。摄影技术具有很高的轴测量重现性,连续测量变化小于2.0度。 1个月时的平均UDVA为0.16 logMAR(0.42至-0.18 logMAR的范围),而6个月时的平均UDVA为0.20 logMAR(0.60至-0.20 logMAR的范围)。自折射的剩余屈光柱面分别为-0.84 D(范围-2.00至0.00 D)和-0.80 D(范围-1.75至0.00 D)。结论:丙烯酸环面IOL在术后头6个月内旋转稳定。用照相和轴分析方法评估稳定性具有很高的可重复性,并且检测到旋转变化很小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号