首页> 外文期刊>Journal of cataract and refractive surgery >Correlation between estimated and measured corneal ablation and refractive outcomes in laser in situ keratomileusis for myopia.
【24h】

Correlation between estimated and measured corneal ablation and refractive outcomes in laser in situ keratomileusis for myopia.

机译:近视眼激光原位角膜磨镶术估计和测量的角膜消融与屈光结果之间的相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the difference between the measured and the intended postoperative central corneal thickness (CCT) by optical low-coherence reflectometry (OLCR) for 3 months after myopic laser in situ keratomileusis (LASIK) and correlate it with refractive outcomes. SETTING: Center for Refractive Therapy, Department of Ophthalmology, Ludwig-Maximilians-University Munich, Germany. METHODS: The CCT was measured by OLCR before and 6 weeks and 3 months after myopic LASIK. The correlation between the difference in pachymetry and the difference in the measured and planned postoperative refraction was proven by linear regression and Pearson product moment correlation analysis (P<.05). In a subset of eyes with a 7.0 mm optical zone, the effect of the calculated ablation depth on the difference in pachymetry was evaluated. Based on the laser algorithm data, the intended ablation was 100 microm or less in Subgroup 1 and 100 microm or more in Subgroup 2. RESULTS: Forty-three eyes of 25 patients were evaluated, with 25 eyes in the subset. The difference between the measured and intended postoperative CCT was 11.1 microm +/- 8.1 (SD) at 6 weeks and 13.8 +/- 7.5 microm at 3 months. The correlation between this difference and the difference in refraction was poor (r(2) = 0.005 microm and r(2) = 0.009, respectively). With greater ablation depth (Subgroup 2), the difference in pachymetry decreased by 3 months postoperatively. CONCLUSION: The lack of correlation between differences in the measured and intended CCT and the final refraction shows the complexity of intraoperative variables in LASIK and the effect of individual wound healing.
机译:目的:通过近视激光原位角膜磨镶术(LASIK)术后3个月的光学低相干反射法(OLCR)评估测得的和预期的术后中央角膜厚度(CCT)之间的差异,并将其与屈光结果相关联。地点:德国慕尼黑路德维希-马克西米利安斯大学眼科屈光治疗中心。方法:在近视LASIK术前,术后6周和3个月通过OLCR测量CCT。线性回归和皮尔逊乘积矩相关分析证明了测厚法差异与术后测量屈光度和计划屈光度之间的相关性(P <.05)。在具有7.0 mm光学区域的眼睛子集中,评估了计算的消融深度对测厚仪差异的影响。根据激光算法数据,预期的消融在亚组1中为100微米或以下,在亚组2中为100微米或以上。结果:评估了25例患者的43眼,其中25眼为亚组。术后第6周测得的CCT与预期的术后CCT之间的差为11.1 +/- 8.1(SD),第3个月时为13.8 +/- 7.5微米。该差与折射差之间的相关性较差(r(2)= 0.005微米和r(2)= 0.009)。随着消融深度的增加(亚组2),术后3个月测厚仪的差异减小。结论:所测得的CCT与预期的CCT之间的差异与最终屈光之间缺乏相关性,表明LASIK术中变量的复杂性以及单个伤口愈合的效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号