首页> 外文期刊>Journal of cataract and refractive surgery >isual function after implantation of an aspheric bifocal intraocular lens
【24h】

isual function after implantation of an aspheric bifocal intraocular lens

机译:非球面双焦点人工晶状体植入后的视觉功能

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (I0L) implantation.SETTING: Fernandez-Vega Ophthalmological Institute, Oviedo, Spain.METHODS: Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0,60.0,50.0 cm) acuities, and contrast sensitivity under phot-opic (85.0 candelas [cd]/m2) and mesopic (3.0 cd/m2) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered.RESULTS: Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, -0.064 +- 0.049 (SD); best corrected near, -0.041 +- 0.061; best corrected intermediate, 0.147 +- 0.130 (70.0 cm), 0.036 +- 0.133 (60.0 cm), and -0.126 +- 0.077 (50.0 cm). The BCVA and best corrected near acuity were 20/25 or better in all patients. Through-focus binocular logMAR acuities had 2 peaks at the expected far focus and near focus (0.00 diopter [D] and -2.40 D, respectively), with somewhat reduced acuity (20/32) at intermediate distances. Photopic contrast sensitivity was within the standard normal range. Mesopic contrast sensitivity was lower than under photopic conditions, particularly at higher spatial frequencies. Patients reported good performance for distance, near, and intermediate visual tasks with no or minimal difficulty with specific tasks. No patient reported severe visual phenomena; halos and glare were rated as none to moderate.CONCLUSIONS: The aspheric I0L provided good functional vision at far and near, with lower performance at intermediate distance; good photopic contrast sensitivity and lower mesopic performance; and a low incidence of visual disturbances.
机译:目的:评估双焦点非球面AcrySof ReSTOR SN6AD1人工晶状体(I0L)植入后的远视,近视和近视。背景:西班牙奥维耶多Fernandez-Vega眼科研究所方法:双眼距离最佳矫正视力(BCVA)(4.0 m ),近距离(40.0 cm)和中间(70.0,60.0,50.0 cm)视力的最佳距离校正,以及在使用(术后无眩光。结果:术后六个月的平均视力(logMAR)为双眼BCVA,-0.064±0.049(SD);双眼BCVA为-0.064±0.049(SD)。最佳校正附近-0.041 +-0.061;最佳校正中间体0.147±0.130(70.0厘米),0.036±0.133(60.0厘米)和-0.126±0.077(50.0厘米)。所有患者的BCVA和最佳矫正近视度数均为20/25或更高。通过焦点的双眼logMAR视力在预期的远焦点和近焦点处分别有2个峰值(分别为0.00屈光度[D]和-2.40 D),在中间距离处视力有所降低(20/32)。视觉对比度敏感度在标准正常范围内。中观对比敏感度低于在明暗条件下,特别是在较高的空间频率下。患者报告在远距离,近距离和中等视觉任务上表现良好,对特定任务没有或仅有最小难度。没有患者报告严重的视觉现象;结论:非球面I0L在远近提供良好的功能视觉,在中距离表现较低。良好的明暗对比敏感度和较低的中观性能;视觉障碍的发生率低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号