Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery.

机译:近视受激准分子激光手术后使用Pentacam Scheimpflug相机测量角膜屈光力。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate corneal power measurements by a rotating Scheimpflug camera (Pentacam, Oculus) in eyes that have had myopic excimer laser surgery. SETTING: Private practice, Bologna, Italy. METHODS: This prospective comparative interventional case series comprised 16 eyes of 16 patients who had myopic excimer laser surgery and for whom all perioperative data were available. Four corneal power measurements obtained with the Pentacam (simulated keratometry, true net power, equivalent K reading, and BESSt formula) were analyzed and compared with values derived using the clinical history method and 2 other formulas for calculating corneal power after refractive surgery (modified keratometric refractive index according to Savini et al. and separate consideration of the anterior and posterior corneal curvatures according to Speicher). RESULTS: Analysis of variance showed a statistically significant difference between all methods (P<.0001). Bonferroni multiple comparison tests showed that the only Pentacam measurements not statistically different from the corneal power values derived using the clinical history method were the equivalent K readings at 1.0 mm, 2.0 mm, and 3.0 mm and those derived with the BESSt formula; however, considerably large 95% limits of agreement (LoA) were calculated between each of these values and those obtained with the clinical history method. CONCLUSIONS: The Pentacam device gave corneal power measurements that did not statistically significantly had differ from those predicted by the clinical history method in eyes that had previous myopic excimer laser surgery. Wide LoA are a potential source of error in intraocular lens power calculation in such patients.
机译:目的:通过旋转Scheimpflug相机(Pentacam,Oculus)评估近视准分子激光手术眼睛的角膜屈光度测量。地点:意大利博洛尼亚的私人诊所。方法:该前瞻性比较介入病例系列由16例近视受激准分子激光手术患者的16眼组成,这些患者的围手术期数据均可用。分析了使用Pentacam获得的四次角膜屈光度测量值(模拟角膜曲率法,真实净屈光度,等效K读数和BESSt公式),并将其与使用临床病史方法和其他2个公式计算出的屈光手术后角膜屈光力的值(修正角膜曲率法) (根据Savini等人的观点),并且根据Speicher)分别考虑角膜前和后角的曲率。结果:方差分析显示所有方法之间的统计学差异(P <.0001)。 Bonferroni多重比较测试显示,与使用临床病史方法得出的角膜屈光力值没有统计学差异的唯一Pentacam测量值是在1.0 mm,2.0 mm和3.0 mm处的等效K读数以及通过BESSt公式得出的K读数。但是,在这些值中的每个值与通过临床病史方法获得的值之间,都计算出相当大的95%一致限(LoA)。结论:Pentacam装置对角膜屈光度的测量与先前使用近视准分子激光手术的眼睛的临床病史方法所预测的差异无统计学意义。在此类患者中,宽LoA是人工晶状体屈光力计算中潜在的错误来源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号