首页> 外文期刊>Journal of cataract and refractive surgery >Online optical coherence pachymetry as a safety measure for laser in situ keratomileusis treatment in 1859 cases.
【24h】

Online optical coherence pachymetry as a safety measure for laser in situ keratomileusis treatment in 1859 cases.

机译:在线光学相干测厚法作为激光原位角膜磨镶术治疗的安全措施1859例。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To evaluate the reliability and applicability of online optical coherence pachymetry (OCP) (OCPonline, Heidelberg Engineering GmbH) integrated into the Zyoptix 217z100 excimer laser platform (Bausch & Lomb) under routine clinical conditions. SETTING: Private laser clinic, Munich, Germany. METHODS: Between July 2004 and June 2006, 1859 consecutive eyes having laser in situ keratomileusis (LASIK) using the Zyoptix 217z100 excimer laser platform had preoperative pachymetry with the Orbscan II (Bausch & Lomb) and DGH II (Pachette 2, DGH Technology, Inc.) and continuous intraoperative online OCP with the OCPonline. Preoperative pachymetry values and actual flap thicknesses with the Hansatome and Zyoptix XP microkeratomes (both Bausch & Lomb) and the IntraLase FS30 femtosecond laser keratome (IntraLase Corp.) were evaluated. RESULTS: Preoperative pachymetry values showed a high correlation between the OCPonline device and the Orbscan II (R(2) = 0.78, difference = 0.37%) and DGH II (R(2) = 0.77, difference = 0.69%). The OCPonline measurements resulted in a mean flap thickness of 121.4 microm +/- 19.1 (SD) with the Hansatome (160 microm head), 126.5 +/- 15.5 microm with the Zyoptix XP (120 microm head), and 121.7 +/- 14.7 microm with the IntraLase FS30 (110 microm flap thickness). A correlation between the calculated laser ablation depth and the measured stromal thinning was established. CONCLUSION: OCPonline technology provided reliable intraoperative noncontact pachymetry measurements integrated into a clinical flow, indicating the technology has the potential to improve the safety of corneal ablation procedures.
机译:目的:评估在常规临床条件下集成到Zyoptix 217z100准分子激光平台(Bausch&Lomb)中的在线光学相干测厚法(OCP)(OCPonline,海德堡工程有限公司)的可靠性和适用性。地点:德国慕尼黑的私人激光诊所。方法:在2004年7月至2006年6月之间,使用Zyoptix 217z100受激准分子激光平台对1859眼连续进行原位角膜磨镶术(LASIK)的眼进行术前测厚,采用Orbscan II(Bausch&Lomb)和DGH II(Pachette 2,DGH Technology,Inc. 。)以及使用OCPonline进行持续的术中在线OCP。使用Hansatome和Zyoptix XP微型角膜刀(均为Bausch&Lomb)和IntraLase FS30飞秒激光角膜刀(IntraLase Corp.)评估术前测厚值和实际瓣厚度。结果:术前测厚仪值显示OCPonline设备与Orbscan II(R(2)= 0.78,差异= 0.37%)和DGH II(R(2)= 0.77,差异= 0.69%)之间具有高度相关性。 OCPonline测量得出Hansatome(160微米头)的平均瓣厚度为121.4微米+/- 19.1(SD),Zyoptix XP(120微米头)的平均瓣厚度为126.5 +/- 15.5微米和121.7 +/- 14.7使用IntraLase FS30的最大厚度(110微米的盖厚度)。建立了计算的激光烧蚀深度与测得的基质间变之间的相关性。结论:OCPonline技术提供了可靠的术中非接触式测厚仪测量,并将其集成到临床流程中,表明该技术具有改善角膜消融手术安全性的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号