首页> 外文期刊>Journal of cataract and refractive surgery >Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges.
【24h】

Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges.

机译:使用带有C和D盒的Monarch注射器系统在SN60WF人工晶状体植入前后的切口尺寸。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate incision sizes for 6.0 mm optic hydrophobic acrylic intraocular lenses (IOLs) implanted with different injector systems and surgical techniques. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt, Germany. METHODS: In this prospective randomized trial of 100 cataract patients, hydrophobic acrylic IOLs (SN60WF) were implanted using 2 injector systems with 2 cartridges (Monarch II and Monarch III with C and D cartridges, respectively; Alcon) and 2 surgical techniques (direct implantation and wound-assisted docking implantation). Incision sizes were measured before and after phacoemulsification as well as before and after IOL implantation using a Tsuneoka microincision gauge. The Saphiro-Wilks test was performed to detect nonparametric distribution and the Kruskal-Wallis test, to test for significant differences between groups. RESULTS: The mean incision sizes (mm) at the 4 points of treatment with the Monarch III with the D cartridge were 1.98+/-0.07, 2.01+/-0.05, 2.42+/-0.07, and 2.51+/-0.05, respectively, with direct implantation and 1.92+/-0.06, 1.98+/-0.04, 2.02+/-0.11, and 2.09+/-0.11, respectively, with wound-assisted implantation. With the Monarch II with the C cartridge, the mean incision sizes were 2.17+/-0.06, 2.2+/-0.16, 2.77+/-0.11, and 2.86+/-0.11, respectively, with direct implantation and 2.12+/-0.10, 2.17+/-0.19, 2.19+/-0.09, and 2.28+/-0.08, respectively, with wound-assisted implantation. Postoperative incision sizes differed significantly from preoperative incision sizes and from each other (P<.05). CONCLUSION: With new injector systems and an appropriate docking implantation technique, foldable hydrophobic acrylic IOLs can be implanted through 2.0 mm tunnel incisions.
机译:目的:评估植入不同注射器系统和手术技术的6.0 mm光学疏水性丙烯酸人工晶状体(IOL)的切口尺寸。地点:德国法兰克福约翰·沃尔夫冈·歌德大学眼科。方法:在这项对100名白内障患者进行的前瞻性随机试验中,使用2个带2个子弹头的注射器(Monarch II和Monarch III分别带有C和D子弹头; Alcon)和2种手术技术(直接植入)植入疏水性丙烯酸IOL(SN60WF)。和伤口辅助对接植入)。使用Tsuneoka微切口规在超声乳化术之前和之后以及在IOL植入之前和之后测量切口大小。进行Saphiro-Wilks检验以检测非参数分布,并进行Kruskal-Wallis检验以检验组之间的显着差异。结果:采用D柱的Monarch III在4个治疗点的平均切口尺寸(mm)分别为1.98 +/- 0.07、2.01 +/- 0.05、2.42 +/- 0.07和2.51 +/- 0.05直接伤口植入,以及伤口辅助植入分别为1.92 +/- 0.06、1.98 +/- 0.04、2.02 +/- 0.11和2.09 +/- 0.11。对于配备C柱的Monarch II,直接植入的平均切口尺寸分别为2.17 +/- 0.06、2.2 +/- 0.16、2.77 +/- 0.11和2.86 +/- 0.11,以及2.12 +/- 0.10 ,2.17 +/- 0.19、2.19 +/- 0.09和2.28 +/- 0.08,分别采用伤口辅助植入。术后切口大小与术前切口大小以及彼此之间有显着差异(P <.05)。结论:使用新的注射器系统和适当的对接植入技术,可通过2.0 mm隧道切口植入可折叠的疏水丙烯酸IOL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号