...
首页> 外文期刊>Journal of cataract and refractive surgery >Histopathological findings after intracorneal ring segment implantation in keratoconic human corneas.
【24h】

Histopathological findings after intracorneal ring segment implantation in keratoconic human corneas.

机译:角膜圆锥形人角膜植入角膜内环段后的组织病理学发现。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate histopathological changes induced in keratoconic corneas after implantation of Intacs intracorneal ring segments (Addition Technology, Inc.). SETTING: Departments of Ophthalmology and Pathology, Hospital Pellegrin, Bordeaux, France. METHODS: This retrospective study included 8 keratoconic, contact-lens-intolerant eyes of 8 patients who had penetrating keratoplasty (PKP) after removal of Intacs inserts because of a poor refractive outcome or insert extrusion. Light microscopy was performed on all specimens after conventional staining. Immunohistochemistry was performed to identify cell types located next to the tunnel using AE1/AE3 cytokeratins, CD34, vimentin, collagen IV, and alpha-smooth muscle actin monoclonal antibodies. RESULTS: Conventional histology showed hypoplasia of the epithelium immediately surrounding the channel. There was no evidence of an inflammatory response or foreign-body granuloma. Keratocyte density was decreased above and below the tunnel, and collagen IV synthesis was seen in the scar area. All samples stained negatively with alpha-smooth muscle actin, indicating that myofibroblasts were not present. These changes were no longer visible when PKP was performed more than 6 months after Intacs explantation. CONCLUSIONS: Intacs induced keratocyte apoptosis, probably through a switch to a collagenous synthetic phenotype. Although histological changes seem to be entirely reversible after implant removal, longer follow-up is necessary to determine whether they accelerate corneal thinning and keratoconus progression via apoptosis and release of metalloprotease.
机译:目的:评估Intacs角膜内环段植入后在圆锥角膜诱导的组织病理学变化(Addition Technology,Inc.)。地点:法国波尔多佩莱格林医院眼科和病理科。方法:这项回顾性研究纳入了8例因屈光不佳或插入物挤出而去除Intacs插入物后进行穿透性角膜移植术(PKP)的8例圆锥角膜,无接触镜的眼睛。常规染色后,对所有样品进行光学显微镜检查。使用AE1 / AE3细胞角蛋白,CD34,波形蛋白,胶原IV和α平滑肌肌动蛋白单克隆抗体进行免疫组织化学以鉴定位于隧道旁的细胞类型。结果:常规组织学检查显示通道周围的上皮细胞发育不全。没有证据表明有炎症反应或异物肉芽肿。隧道上方和下方的角质形成细胞密度降低,并且在瘢痕区域可见胶原IV合成。所有样品均被α-平滑肌肌动蛋白染色阴性,表明不存在肌成纤维细胞。当Intacs植入后超过6个月进行PKP时,这些变化不再可见。结论:Intacs可能诱导了角质形成细胞凋亡,可能是通过转变为胶原合成表型。尽管摘除植入物后组织学改变似乎是完全可逆的,但需要更长的随访以确定它们是否通过凋亡和金属蛋白酶的释放来加速角膜变薄和圆锥角膜的进展。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号