...
首页> 外文期刊>Journal of cataract and refractive surgery >Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment.
【24h】

Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment.

机译:前段光学相干断层扫描和超声生物显微镜对前段评估的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare anterior segment parameters using quantitative imaging by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). SETTING: Tertiary-care glaucoma research center. METHODS: Sixty-three eyes of 63 subjects had anterior segment evaluation by AS-OCT (Visante-Zeiss) and UBM (Paradigm). Central corneal thickness (CCT), anterior chamber depth (ACD) (measured from the central corneal endothelium to the anterior lens capsule), and the peripheral iridocorneal angles (temporal and nasal) were assessed and compared. RESULTS: There was an excellent correlation between AS-OCT and UBM measurements for the nasal angle (r = 0.84; P<.0001), temporal angle (r = 0.86; P<.0001), ACD (r = 0.97; P<.0001), and CCT (r = 0.91; P<.0001). There was no significant difference (paired t test) between the mean ACD, CCT, and angle parameters measured by AS-OCT or UBM. The mean values of the parameters measured by AS-OCT and UBM were, respectively, as follows: nasal angle, 26.25 degrees +/- 11.0 (SD) and 28.27 +/- 11.3 degrees (P = .3); temporal angle, 25.1 +/- 11.4 degrees and 28.3 +/- 13.5 degrees (P = .15); ACD, 2.85 +/- 0.5 mm and 2.78 +/- 0.5 mm (P = .2); and CCT, 512 +/- 46 microm and 502 +/- 46 microm (P = .25). The AS-OCT images showed sharper definition of the scleral spur than the UBM images. CONCLUSION: Anterior segment optical coherence tomography and UBM can both be used for anterior segment measurements and yielded comparable results.
机译:目的:使用前节光学相干断层扫描(AS-OCT)和超声生物显微镜(UBM)通过定量成像比较前节参数。单位:三级青光眼研究中心。方法:对63名受试者的63只眼进行了AS-OCT(Visante-Zeiss)和UBM(Paradigm)评估。评估并比较中央角膜厚度(CCT),前房深度(ACD)(从中央角膜内皮到前晶状体囊测量)和周边虹膜角膜角(颞侧和鼻侧)。结果:AS-OCT和UBM测量值在鼻角(r = 0.84; P <.0001),颞角(r = 0.86; P <.0001),ACD(r = 0.97; P < .0001)和CCT(r = 0.91; P <.0001)。平均ACD,CCT和AS-OCT或UBM测量的角度参数之间没有显着差异(配对t检验)。 AS-OCT和UBM测量的参数平均值分别为:鼻角26.25 +/- 11.0(SD)和28.27 +/- 11.3度(P = 0.3);颞角25.1 +/- 11.4度和28.3 +/- 13.5度(P = 0.15); ACD 2.85 +/- 0.5毫米和2.78 +/- 0.5毫米(P = 0.2);和CCT,512 +/- 46微米和502 +/- 46微米(P = .25)。与UBM图像相比,AS-OCT图像显示出的巩膜骨刺清晰度更高。结论:前节光学相干断层扫描和UBM均可用于前节测量,并产生可比的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号