...
首页> 外文期刊>Journal of cataract and refractive surgery >New method to measure the retention of viscoelastic agents on a rabbit corneal endothelial cell line after irrigation and aspiration.
【24h】

New method to measure the retention of viscoelastic agents on a rabbit corneal endothelial cell line after irrigation and aspiration.

机译:冲洗和抽吸后测量粘弹性剂在兔角膜内皮细胞系中保留的新方法。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To quantify the surface retention of several ophthalmic viscoelastic agents following irrigation and aspiration (I/A) using a new in vitro method. SETTING: Alcon Laboratories, Inc., Fort Worth, Texas, USA. METHODS: A rabbit corneal endothelial cell line was cultured to confluency in 24-well plates, and the cells were labeled quantitatively with internalized neutral red dye. Five ophthalmic viscoelastic agents were applied to cover the monolayer of cells: sodium hyaluronate (Healon, Provisc, and Amvisc Plus), Formulation A (a dispersive, nonproteinaceous, synthetic polymer), and sodium chondroitin sulfate, sodium hyaluronate (Viscoat). Irrigation and aspiration (with fluid turbulence similar to that encountered in phacoemulsification surgery) were performed on each well for 3 minutes, using 120 mL of balanced salt solution with bicarbonate. dextrose, and glutathione (BSS Plus). The cells were treated with an acidified ethanol solution to extract the dye from the cells left without a viscoelastic cover. The extracted dye was measured by spectrophotometry and compared with the total dye recovered from control cells. RESULTS: The retention value, which represented the percentage of cells with viscoelastic retained on the surface, was calculated as follows: Healon, 7; Provisc, 16; Amvisc Plus, 17; Formulation A, 55; Viscoat, 90. On a nonadsorptive, non-cell surface, the retention values of the five viscoelastics were significantly less than those on cells. CONCLUSION: The results of this experimental model suggest that cohesive viscoelastics are readily removed from the cells, while dispersive viscoelastics are highly retained. In addition, mutual surface interaction (electrical charge and other properties) plays a significant role in determining the retention of viscoelastics on the corneal endothelial cell surface following I/A.
机译:目的:使用一种新的体外方法量化冲洗和抽吸(I / A)后几种眼科粘弹性剂的表面保持力。地点:美国德克萨斯州沃思堡的爱尔康实验室有限公司。方法:在24孔板中培养兔角膜内皮细胞系至汇合,并用内在的中性红色染料定量标记细胞。施加了五种眼科粘弹性剂以覆盖单层细胞:透明质酸钠(Healon,Provisc和Amvisc Plus),配方A(一种分散的,非蛋白质的合成聚合物)和硫酸软骨素钠,透明质酸钠(Viscoat)。使用120 mL碳酸氢盐平衡溶液在每口井上进行3分钟的灌溉和抽吸(流体紊流与超声乳化术中所遇到的相似)。葡萄糖和谷胱甘肽(BSS Plus)。用酸化的乙醇溶液处理细胞,以从没有粘弹性覆盖物的剩余细胞中提取染料。通过分光光度法测量提取的染料,并将其与从对照细胞回收的总染料进行比较。结果:保留值代表表面粘弹性保留的细胞的百分比,计算如下:Healon,7; Healon,7; Healon,7。 Provisc,16岁; Amvisc Plus,17岁;配方A,55; 90. Viscoat,在非吸附性,非细胞表面上,五种粘弹性材料的保留值明显小于在细胞上的保留值。结论:该实验模型的结果表明,粘性粘弹性很容易从细胞中去除,而分散性粘弹性被高度保留。另外,在I / A后,相互表面相互作用(电荷和其他性质)在确定粘弹性在角膜内皮细胞表面上的保留中起着重要作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号