首页> 外文期刊>Journal of cataract and refractive surgery >Rotational stability and visual outcome after implantation of a new toric intraocular lens for the correction of corneal astigmatism during cataract surgery
【24h】

Rotational stability and visual outcome after implantation of a new toric intraocular lens for the correction of corneal astigmatism during cataract surgery

机译:植入新的复曲面人工晶状体以矫正白内障手术中角膜散光后的旋转稳定性和视觉效果

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate rotational stability and the refractive and visual outcomes of a new aspheric toric intraocular lens (IOL) for correction of preexisting corneal astigmatism during routine cataract surgery. Setting: Department of Ophthalmology, Paracelsus Medical University Salzburg, Salzburg, Austria. Design: Case series. Methods: Aspheric Bi-Flex T toric IOLs were monolaterally or bilaterally implanted after phacoemulsification in patients with topographic corneal astigmatism between 1.5 diopters (D) and 4.0 D. Preoperative IOL calculations were performed by laser interference biometry (Haigis formula). Appropriate IOL-torus alignment was facilitated by combined imaging and eye-tracking technology. Refraction and uncorrected distance (UDVA) and corrected distance visual acuities were measured 1 day, 1 week, and 1 and 3 months postoperatively. At each visit, photodocumentation in retroillumination was performed to evaluate torus position and potential toric IOL rotation. Results: The mean refractive astigmatism decreased from 1.93 D ± 0.90 (SD) (range 0.5 to 4.0 D) to 0.30 ± 0.54 D (range 0.0 to 1.5 D) at 3 months. Patients achieved a mean UDVA of 0.05 ± 0.12 logMAR (range -0.18 to 0.30 logMAR [~20/20]). Intraoperative to 3-month postoperative comparison of IOL axis alignment showed low levels of rotation (mean 2.12 ± 3.45 degrees; range -2 to +5 degrees). Conclusions: Implantation of the new aspheric toric IOL was effective, safe, and stable in correcting preexisting regular corneal astigmatism during cataract surgery. Combined imaging and eye tracking seems to be a promising technology to evaluate the correct axis for IOL torus alignment. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:评估一种新的非球面复曲面人工晶状体(IOL)的旋转稳定性以及屈光和视觉效果,以矫正常规白内障手术中已存在的角膜散光。地点:奥地利萨尔茨堡萨尔茨堡Paracelsus医科大学眼科。设计:案例系列。方法:超声乳化术在1.5屈光度(D)至4.0 D之间的角膜散光患者中,单侧或双侧植入非球面Bi-Flex T复曲面IOL。术前IOL的计算通过激光干扰生物测定法(Haigis公式)进行。结合的成像和眼动追踪技术可促进适当的IOL眼眶对准。术后1天,1周以及1和3个月测量屈光度和未矫正距离(UDVA)以及矫正距离视力。每次访视时,都要进行回射照像的照相记录,以评估环面的位置和潜在的复曲面IOL旋转。结果:3个月时,平均屈光散光从1.93 D±0.90(SD)(范围0.5至4.0 D)降至0.30±0.54 D(范围0.0至1.5 D)。患者的平均UDVA为0.05±0.12 logMAR(-0.18至0.30 logMAR [〜20/20])。术中至术后3个月IOL轴对准的比较显示低水平旋转(平均2.12±3.45度;范围-2至+5度)。结论:新的非球面复曲面人工晶状体植入术在矫正白内障手术期间已存在的常规角膜散光方面是有效,安全且稳定的。结合成像和眼动追踪似乎是评估IOL环面对准的正确轴的有前途的技术。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号