【24h】

Cataract surgical problem

机译:白内障手术问题

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

This patient is experiencing the classic problems associated with implantation of an oversized AC IOL. They include iris tuck, iris atrophy, ovalization of the pupil, ectropion pupillae, anterior synechiae, globe tenderness, and corneal decompensation. Although no mention was made of glaucomatous optic nerve changes, the IOP in the right eye is twice that in the left eye and will have to be monitored going forward. The classic starting point for sizing an AC IOL is the horizontal corneal WTW diameter + 1.0 mm. If after implantation, an IOL is found to be oversized or undersized, it should be exchanged immediately to prevent the problems that developed here.
机译:该患者正在经历与植入超大型AC IOL相关的经典问题。它们包括虹膜t,虹膜萎缩,瞳孔椭圆化,瞳孔外翻,前粘连,球体压痛和角膜代偿失调。尽管没有提及青光眼性视神经的改变,但右眼的IOP是左眼的两倍,因此必须对其进行监视。确定AC IOL尺寸的经典起点是水平角膜WTW直径+ 1.0 mm。如果植入后发现IOL尺寸过大或过小,应立即进行更换以防止此处出现问题。