On the physical consistency between three-dimensional and one-dimensional models in haemodynamics

机译:血液动力学中三维模型与一维模型之间的物理一致性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this work we discuss the reliability of the coupling among three-dimensional (3D) and one-dimensional (1D) models that describe blood flowing into the circulatory tree. In particular, we study the physical consistency of the 1D model with respect to the 3D one. To this aim, we introduce a general criterion based on energy balance for the proper choice of coupling conditions between models. We also propose a way to include in the 1D model the effect of the external tissue surrounding the vessel and we discuss its importance whenever this effect is considered in the 3D model. Finally, we propose several numerical results in real human carotids, studying different configurations for the 1D model and highlighting the best one in view of the physical consistency.
机译:在这项工作中,我们讨论了描述血液流入循环树的三维(3D)模型和一维(1D)模型之间耦合的可靠性。特别是,我们研究了1D模型相对于3D模型的物理一致性。为此,我们引入了一个基于能量平衡的通用准则,以正确选择模型之间的耦合条件。我们还提出了一种在1D模型中包括血管周围外部组织的影响的方法,并且每当在3D模型中考虑这种影响时,我们都会讨论其重要性。最后,我们提出了一些关于实际人类颈动脉的数值结果,研究了一维模型的不同配置,并从物理一致性的角度突出了最佳模型。