首页> 外文期刊>Clinical biomechanics >Biomechanical comparison of three 2.7-mm screws and two 3.5-mm screws for fixation of simple oblique fractures in human distal fibulae
【24h】

Biomechanical comparison of three 2.7-mm screws and two 3.5-mm screws for fixation of simple oblique fractures in human distal fibulae

机译:三个2.7 mm螺钉和两个3.5 mm螺钉固定人远端腓骨简单斜性骨折的生物力学比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Fixation of simple oblique fractures of short tubular bones with only inter-fragmentary screws is simple and clinically useful. This study compared the biomechanical properties of fixation using three 2.7-mm mini-screw and two conventional 3.5-mm lag screw constructs for simple oblique fractures of the distal fibula in human osteoporotic bone. Methods: Simple oblique fractures of the distal fibula at the level of the syndesmosis were simulated in 15 paired fresh frozen ankles, and the calcaneal bone mineral density was measured in each. Fixation with either three 2.7-mm mini-screws (new system) or two 3.5-mm cortical screws (conventional system) was performed in each pair of ankles. The sample size for each type of stress (cantilever bending stress, five pairs; external rotational load to failure, 10 pairs) was calculated before the test. The biomechanical variables (maximal failure load and construct stiffness) of the two fixation groups were compared using a non-inferiority test method with a pre-specified non-inferiority margin. Findings: The bone mineral density of the calcaneus was assessed as osteoporotic based on reference values for 20- to 29-year-old healthy Koreans. The new system was not inferior to the conventional system in terms of the tested biomechanical properties. The construct failure was initiated from the distal-most screw hole in the anterior cortex. Interpretation: Fixation with only three 2.7-mm mini-screws provided biomechanical stability comparable to two 3.5-mm cortical screws for simple oblique osteoporotic fractures in the distal fibula under one-shot stress. Mini-screw application for this common fracture might extend the scope of surgical indications for the screws-only fixation method.
机译:背景:仅使用碎骨间螺钉固定短管状骨的简单斜性骨折很简单,在临床上很有用。这项研究比较了使用三个2.7毫米微型螺钉和两个传统的3.5毫米拉力螺钉构造物对人骨质疏松性骨远端腓骨简单斜性骨折进行固定的生物力学特性。方法:在15对成对的新鲜冷冻踝关节中模拟腓骨远端腓骨简单斜交骨折,并分别测量跟骨的矿物质密度。在每对脚踝中用三个2.7毫米微型螺钉(新系统)或两个3.5毫米皮质螺钉(常规系统)进行固定。在测试前计算每种应力类型的样品大小(悬臂弯曲应力,五对;破坏时的外部旋转载荷,十对)。使用非劣效性测试方法和预先指定的非劣效性余量比较两个固定组的生物力学变量(最大破坏载荷和结构刚度)。结果:根据20至29岁健康韩国人的参考值,将跟骨的骨矿物质密度评估为骨质疏松症。在测试的生物力学性能方面,新系统并不逊色于常规系统。构造失败是从前皮质的最远端螺丝孔开始的。解释:仅用三个2.7 mm微型螺钉进行固定即可提供与两个3.5 mm皮质螺钉相当的生物力学稳定性,以解决一次性应力作用下腓骨远端的简单斜性骨质疏松性骨折。对于这种常见的骨折,微型螺钉的应用可能会扩大仅螺钉固定方法的手术适应症范围。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号