The effect of loading rate and degeneration on neutral region motion in human cadaveric lumbar motion segments.

机译:负荷率和退化对人体尸体腰椎运动段中性区域运动的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The quasistatic neutral zone is a surrogate for neutral region stiffness of spinal motion segments. No similar measure of dynamic stiffness has been validated. Because parameters related to stiffness are likely to be affected by loading rate and disc degeneration, we examined the effect of those factors on motion parameters derived from continuous motion data. METHODS: Fifteen human lumbar motion segments were tested with continuous flexion-extension pure moments at 0.5, 3.0 and 6.0 degrees /s. Range of motion, width of the hysteresis loop, transitional zone width, and slopes of the upper and lower arms of the hysteresis loop within the transitional zone were measured. Discs were then graded for degeneration. FINDINGS: As the loading rate increased from 0.5 degrees /s to 6.0 degrees /s there were significant increases in range of motion, hysteresis area, hysteresis loop width, and the upper and lower transitional zone slopes. At the same time transitional zone width decreased significantly.Degeneration had a significant effect on all parameters except hysteresis loop width. The transition zone slopes appeared to best discriminate between normal and degenerative discs. INTERPRETATION: Loading rate had a significant effect on all parameters. As degeneration increased consistent effects were observed indicating decreasing stiffness from grade 1 to grade 3 then slightly increased stiffness in grade 4 specimens. The slopes of the transitional zone have potential to be a useful measure of neutral region stiffness during dynamic motion testing.
机译:背景:准静态中性区是脊柱运动节段中性区刚度的替代物。没有类似的动态刚度测量方法得到验证。由于与刚度有关的参数可能受加载速率和椎间盘退变的影响,因此我们检查了这些因素对从连续运动数据得出的运动参数的影响。方法:以0.5、3.0和6.0度/ s的连续屈伸纯力矩测试了15个人的腰椎运动段。测量运动范围,磁滞回线的宽度,过渡区域的宽度以及过渡区域内磁滞回线的上下臂的斜率。然后将光盘分级以进行变性。研究结果:随着加载速率从0.5度/秒增加到6.0度/秒,运动范围,滞后面积,滞后回线宽度以及上下过渡区域斜率都有显着增加。同时,过渡区宽度显着减小。退化对除磁滞回线宽度以外的所有参数都有显着影响。过渡带斜率似乎可以最好地区分正常盘和退化盘。解释:加载速率对所有参数都有显着影响。随着变性的增加,观察到一致的影响,表明刚度从1级降低到3级,然后在4级标本中略有增加。过渡区的坡度有可能成为动态运动测试期间中性区刚度的有用度量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号