首页> 外文期刊>Clinical biomechanics >Does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? A biomechanical study.
【24h】

Does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? A biomechanical study.

机译:由于插入刀片植入物而引起的松质骨压实会影响抗切强度吗?生物力学研究。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: For the treatment of hip fractures helically shaped implants, like the Dynamic Hip Screw (DHS) Blade, are often used. One consequence of blade implantation, the compaction of cancellous bone, is still believed to increase cut-out resistance. This in vitro study investigates implant anchorage of Dynamic Hip Screw Blades in femoral heads due to insertion with or without predrilling under cyclic physiological loading conditions. METHODS: Six pairs of fresh frozen (-20 degrees C) human cadaveric proximal femora were instrumented with DHS Blades. Bone pairs were randomly assigned to two study groups: 1) predrilled; 2) non-predrilled. Prior instrumentation, bone mineral density was determined in the center of the femoral head by Xtreme-CT measurement. After instrumentation biomechanical testing was performed under cyclic loading. The bone-implant interface was monitored by means of fluoroscopic imaging throughout the experiment. Paired t-tests were performed to identify differences regarding bone mineral density, stiffness and cycles to failure. FINDINGS: No significant differences were found between study groups with regard to axial stiffness (P=0.626) and number of cycles to failure (P=0.961). INTERPRETATION: This in vitro study did not show differences in biomechanical stability of proximal femora instrumented with a helical blade implant with or without predrilling. Clinically, the findings suggest that predrilling may be performed to ease the surgical procedure without compromising the implant anchorage.
机译:背景:为治疗髋部骨折,通常使用螺旋形植入物,例如动态髋螺钉(DHS)刀片。仍然认为,刀片植入的结果之一是松质骨的压实,增加了切开阻力。这项体外研究调查了动态髋关节螺旋刀片在循环生理负荷条件下由于有无预钻插入而在股骨头中的锚固情况。方法:使用DHS刀片对六对新鲜冷冻的(-20摄氏度)人尸体股骨近端进行测量。将骨对随机分配到两个研究组:1)预钻孔; 2)非预钻。事先使用仪器,通过Xtreme-CT测量确定股骨头中央的骨矿物质密度。仪器安装后,在循环载荷下进行生物力学测试。在整个实验过程中,均通过荧光镜对骨-植入物界面进行监测。进行配对的t-检验,以鉴定关于骨矿物质密度,刚度和衰竭周期的差异。结果:研究组之间在轴向刚度(P = 0.626)和失效循环数(P = 0.961)方面没有发现显着差异。解释:这项体外研究未显示使用带或不带有预钻的螺旋刀片植入物对股骨近端生物力学稳定性的差异。临床上,研究结果表明可以进行预钻孔以简化手术程序,而不会损害植入物的固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号