A HPLC-MS-MS method to measure amprenavir in human seminal plasma has been developed and validated. The procedure uses stable, isotopically labeled ~(13)C_6-amprenavir as an internal standard and 100 μl of sample. The method is accurate (bias less than or equal to 7.2%) and precise (within- and between-day RSDs less than or equal to 4.2%) over the dynamic range of 30-4000 ng/ml. Recently, this simple and sensitive method was used to determine amprenavir concentrations in seminal samples collected from HIV-1 positive subjects receiving amprenavir antiretroviral therapy as part of a multicenter clinical trial.
机译:已经开发并验证了一种HPLC-MS-MS方法来测定人精浆中的氨普那韦。该程序使用稳定的,同位素标记的〜(13)C_6-amprenavir作为内标和100μl样品。在30-4000 ng / ml的动态范围内,该方法是准确的(偏差小于或等于7.2%)和精确的(日内和日间RSD小于或等于4.2%)。最近,作为一项多中心临床试验的一部分,这种简单而灵敏的方法被用于确定从接受安普那韦抗逆转录病毒治疗的HIV-1阳性受试者收集的精液样本中的安普那韦浓度。