首页> 外文期刊>Journal of Chromatography, Biomedical Applications >Characterization of a solid-phase extraction device for discontinuous on-line preconcentration in capillary electrophoresis-based peptide mapping
【24h】

Characterization of a solid-phase extraction device for discontinuous on-line preconcentration in capillary electrophoresis-based peptide mapping

机译:基于毛细管电泳的肽图分析中不连续在线预浓缩的固相萃取装置的表征

获取原文
获取原文并翻译 | 示例
           

摘要

Peptide mapping by capillary electrophoresis (CE) with UV detection is problematic for the characterization of proteins that can only be obtained at low micromolar concentrations. Dilution of peptide fragments during digestion of the protein can further reduce th detection sensitivity in peptide mapping to the point where analysis at sub-micromolar concentrations is not possible. A remedy to this problem is preconcentration (sample enrichment) of the proteolytic digest by solid-phase extraction (SPE). To minimize non-specific adsorptive losses during sample handling, on-line SPE-CE is preferred. However, packed-inlet SPE-CE is not always feasible dur to either instrument or sample limitations. We describe here a simple method of preconcentration by discontinuous on-line SPE-CE, specifically applied ot peptide mapping in low-pH separation buffer after protein digestion in a solid-phase enzyme microreactor. The SPE-CE system does not require application of a low pressure during electrophoretic separation to overcome reversed electroosmotic flow because the preconcentrator device is disconnected from the separation capillaryh before the electric field is applied. Up to a 500-fold preconcentration factor can be achieved with this device, which can be reused for many samples. Parameters such as the volume of desorption solution, the adsorption/desorption (chromatographic) process, reproducibility of packing the SPE preconcentrator and effects of sample concentration on the peptide map are investigated.
机译:通过毛细管电泳(CE)和UV检测进行肽图分析对于鉴定只能在低微摩尔浓度下获得的蛋白质而言是一个难题。在蛋白质消化过程中稀释肽片段会进一步降低肽图绘制中的检测灵敏度,以至无法进行亚微摩尔浓度的分析。解决此问题的方法是通过固相萃取(SPE)对蛋白水解消化液进行预浓缩(样品富集)。为了使样品处理过程中的非特异性吸附损失最小化,首选在线SPE-CE。但是,由于仪器或样品的限制,填充进口的SPE-CE并不总是可行的。我们在这里描述了一种通过不连续在线SPE-CE进行预浓缩的简单方法,特别是在固相酶微反应器中的蛋白质消化后,在低pH分离缓冲液中特别应用了ot肽图分析。 SPE-CE系统不需要在电泳分离过程中施加低压来克服反向电渗流,因为在施加电场之前,预浓缩器设备已从分离毛细管上断开。该设备可实现高达500倍的预富集因子,可将其重复用于许多样品。研究了诸如解吸溶液的体积,吸附/解吸(色谱)过程,SPE预浓缩器填充的重现性以及样品浓度对肽图的影响等参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号