首页> 外文期刊>Journal of Chromatography, Biomedical Applications >Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection
【24h】

Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection

机译:高效液相色谱-多电极电化学检测法测定人血清中双酚A

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C-18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection Limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND similar to0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 mi of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 mi of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample were 0.01 ng/ml and 0.05 ng/ml, respectively. The method was applied to the determination of bisphenol A in healthy human serum sample, and the obtained detection was 0.32 ng/ml. From these results, the HPLC-ED method should be the most useful in the determination of bisphenol A at low concentration levels in water and biological samples. (C) 2000 Elsevier Science B.V. All rights reserved. [References: 25]
机译:已开发出一种简单高效的方法,该方法使用高效液相色谱和多电极电化学检测(HPLC-ED)方法,该方法包括电量分析法的四个电化学传感器阵列,用于测定水和人血清中的双酚A。为了良好地分离和检测双酚A,使用了CAPCELL PAK UG 120 C-18反相柱和由0.3%磷酸-乙腈(60:40)组成的流动相。通过HPLC-ED方法获得的检出限为0.01 ng / ml(0.5 pg),比通过紫外线(UV)方法获得的检出限高3000倍,比通过HPLC(ED)方法获得的检出限高200倍。通过荧光(FL)方法获得的检出限。水和血清样品中的双酚A在去除可能来自塑料SPE滤筒和用于预处理的水的污染物后,通过固相萃取(SPE)进行了预处理。通过用甲醇萃取,从色谱柱的各个部分(过滤柱,吸附床和玻璃料)中检测到痕量(ND近似于0.013 ng / ml)双酚A,并用至少15 ml二氯甲烷洗涤,将其完全去除。甲醇在操作过程中。发现自来水和Milli-Q纯化水中的双酚A浓度分别为0.01 ng / ml和0.02 ng / ml。因此,使用Empore圆盘将不含双酚A的水制得,将双酚A捕集在水中。在每次预处理中,都要在水和血清样品中使用不含双酚A的水和用15 mi甲醇洗涤的SPE方法。使用添加了0.5或0.05 ng / ml双酚A的水从回收率测试中获得的产率分别为83.8至98.2%和RSD为3.4至6.1%。使用添加了1.0 ng / ml或0.1 ng / ml双酚A的血清,通过OASIS HLB的回收率测试获得的产率分别为79.0%和87.3%,RSD分别为5.1%和13.5%。水和血清样品中的定量限分别为0.01 ng / ml和0.05 ng / ml。该方法用于健康人血清中双酚A的测定,检出率为0.32 ng / ml。根据这些结果,HPLC-ED方法在测定水和生物样品中的低浓度双酚A时应该是最有用的。 (C)2000 Elsevier Science B.V.保留所有权利。 [参考:25]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号