首页> 外文期刊>Journal of clinical virology: The official publication of the Pan American Society for Clinical Virology >Hybrid Capture II HPV Test detects at least 15 human papillomavirus genotypes not included in its current high-risk probe cocktail.
【24h】

Hybrid Capture II HPV Test detects at least 15 human papillomavirus genotypes not included in its current high-risk probe cocktail.

机译:Hybrid Capture II HPV Test检测出至少15种人类乳头瘤病毒基因型,其目前的高风险探针混合物中未包括。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: Hybrid Capture II HPV Test (HCII) (Digene Corporation, Gaithersburg, MD) is a signal amplified hybridization microplate-based assay designated to detect 18 human papillomavirus (HPV) genotypes using two probe cocktails, for high-risk HPV genotypes 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59 and 68 and low-risk HPV genotypes 6, 11, 42, 43 and 44. At present, HCII is the only commercially available HPV assay with sufficient scientific data to support its performance in the clinical setting. OBJECTIVES: To determine the specificity and accuracy of HCII high-risk probe cocktail for detection of 13 HPV genotypes included in the high-risk probe cocktail. STUDY DESIGN: Cervical samples obtained from 325 women recognized as HPV positive using the HCII high-risk probe cocktail were included in the study. HPV genotypes were determined by restriction fragment analysis of PGMY09/PGMY11 polymerase chain reaction (PCR) products using seven restriction endonucleases. RESULTS: A 450 bp fragment of HPV L1 gene was successfully amplified from 312 out of 325 samples. Of the 312 PCR-positive samples, 280 samples were associated with the expected high-risk HPV genotypes and 32 samples with the HPV genotypes not included in the HCII high-risk probe cocktail. Thus, HPV53 was detected in 8 samples, HPV66 in 4 samples, HPV54 in 3 samples, HPV6, HPV26, HPV70 each in 2 samples, and HPV11, HPV40, HPV42, HPV61, HPV73, HPV81, MM4, IS39, CP6108 each in 1 sample. In 2 samples, we were not able to determine the HPV genotype. CONCLUSIONS: Our study shows that HCII high-risk probe cocktail detects at least 15 HPV genotypes not included in the current HCII high-risk probe cocktail. The potential impact of HCII high-risk probe cocktail cross-reactivity with phylogenetically related and unrelated HPV genotypes, including genotypes currently considered to be low-risk HPVs, remains to be determined.
机译:背景:Hybrid Capture II HPV Test(HCII)(Digene Corporation,Gaithersburg,MD)是一种基于信号扩增杂交微板的检测方法,用于使用两种探针混合物检测18种人乳头瘤病毒(HPV)基因型,用于高风险HPV基因型16, 18、31、33、35、39、45、51、52、56、58、59和68和低风险HPV基因型6、11、42、43和44。目前,HCII是唯一可商购的HPV分析具有足够的科学数据来支持其在临床环境中的表现。目的:确定HCII高风险探针混合物用于检测高风险探针混合物中包含的13种HPV基因型的特异性和准确性。研究设计:使用HCII高风险探针混合物从325名被确认为HPV阳性的女性中获得宫颈样本。通过使用7种限制性核酸内切酶对PGMY09 / PGMY11聚合酶链反应(PCR)产物进行限制性片段分析来确定HPV基因型。结果:成功地从325个样本中的312个中成功扩增了HPV L1基因的450 bp片段。在312个PCR阳性样本中,有280个样本与预期的高风险HPV基因型相关,在HCII高风险探针混合物中未包含32个具有HPV基因型的样本。因此,在8个样本中检测到HPV53,在4个样本中检测到HPV66,在3个样本中检测到HPV54,在2个样本中分别检测到HPV6,HPV26,HPV70,以及在1个样本中分别检测到HPV11,HPV40,HPV42,HPV61,HPV73,HPV81,MM4,IS39,CP6108样品。在2个样本中,我们无法确定HPV基因型。结论:我们的研究表明,HCII高风险探针混合物可检测出至少15种HPV基因型,而这些基因型不包括在当前HCII高风险探针混合物中。 HCII高风险探针鸡尾酒交叉反应与系统发育相关和不相关的HPV基因型(包括当前被认为是低风险HPV的基因型)的潜在影响尚待确定。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号