OBJECTIVE: To compare procalcitonin measurements between semi-quantitative and quantitative assays. METHOD: Procalcitonin was measured with the PCT-Q and the Kryptor assays in a pediatric emergency department. RESULTS: Among the 359 pairs of results, 103 had discordant results. The linear weighted kappa was 0.44 (95% CI 0.36, 0.51). The concordant/discordant results distribution varied depending on the laboratory technician (p=0.018). CONCLUSION: Agreement between procalcitonin measured semi-quantitatively and quantitatively was moderate. This is probably due to a subjective interpretation of the assay result.
机译:目的:比较半定量和定量测定之间降钙素原的测定。方法:在儿科急诊科中通过PCT-Q和Kryptor测定法测定降钙素原。结果:在359对结果中,有103个结果不一致。线性加权卡伯值为0.44(95%CI 0.36,0.51)。一致/不一致结果的分布随实验室技术人员的不同而不同(p = 0.018)。结论:降钙素原的定量和定量结果相符。这可能是由于对测定结果的主观解释。