Stopped-flow kinetics techniques are important to the study of rapid chemical and biochemical reactions. Incorporation of a stopped-flow kinetics experiment into the physical chemistry laboratory curriculum would therefore be an instructive addition. However, the usual reactions studied in such exercises employ a corrosive reagent that can over time cause damage to sensitive and expensive components of a stopped-flow apparatus. The reduction of the dye 2,6-dichlorophenolindophenol by L-ascorbic acid at a pH of 8.5 is a reaction that provides accurate and reproducible data in the physical chemistry laboratory. Furthermore, these reagents are noncorrosiveand protect instrumentation from damage.
机译:停流动力学技术对快速化学和生化反应的研究很重要。因此,将停流动力学实验纳入物理化学实验室课程中将是有益的补充。但是,在此类练习中研究的常规反应使用的是腐蚀性试剂,随着时间的流逝,腐蚀性试剂可能会对停流设备的敏感且昂贵的组件造成损害。在pH值为8.5时,L-抗坏血酸还原染料2,6-二氯苯酚吲哚酚的反应可提供准确且可重现的数据。此外,这些试剂无腐蚀性,可保护仪器免受损坏。