获取原文
获取原文并翻译 | 示例

摘要

Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7mmHgand-0.9+/- 0.5mmHg, respectively), withameanpulsepressureof3.4mmHg.ThedifferencebetweenthemeanCVPandCVPatend- diastoleduringexpirationwas0.58+/- 0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinusrhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
机译:目的。来自中央静脉导管的信息未得到充分利用。我们开发了一个EKG-R同步和平均系统,以获得独特的CVP波形并分析了这些波形的成分。方法。研究了在机械通气下接受CVP监测的25例瘫痪手术患者。使用我们的系统分析CVP和EKG信号,比较呼气末舒张末期的平均CVP和CVP,并使用该系统测量CVP波形分量。结果。所有患者的CVP波形均清晰可见。他们显示一个峰为1.8 +/- 0.7 mmHg,这是三个峰中的最高峰,并且x谷低于y谷(分别为-1.6 +/- 0.7mmHg和-0.9 +/- 0.5mmHg ),脉冲压力为3.4mmHg.CVP和CVP终止呼出的平均压力之差为0.58 +/- 0.81 mmHg。结论。平均CVP可用作有规则窦律的机械通气患者右室预负荷的指标。我们新开发的系统可用于临床监测和循环生理学教育。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号