首页> 外文期刊>Journal of clinical monitoring and computing >Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion
【24h】

Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion

机译:重症患儿外周血灌注不足的床旁血糖仪准确性

获取原文
获取原文并翻译 | 示例
           

摘要

The accuracy of glucose test strip in critically care has been questioned. We investigated the accuracy of glucose test strip in critically ill children. Patients, aged from 1 month to 18 years admitted in pediatric intensive care unit. Demographic data, hemodynamic parameters, and perfusion index (PI) were recorded. Glucose test strips were performed from finger stick blood [capillary blood glucose (CBG)] and from whole blood [whole blood glucose (WBG)] along with laboratory plasma blood glucose (PBG) from either arterial or venous blood samples. The accuracy of glucose test strips was defined according to ISO 15197 and Clarke error grid (CEG). One hundred and eighty one blood samplings including 117 arterial blood (CBG, WBG(a), PBG(a)) and 64 venous blood (CBG, WBG(v), PBG(v)) were obtained. The accuracy of WBG(a) was 98.3 and 95.2 % when compared to the accuracy of CBG (88.7 and 83.3 %. The accuracy of WBG(v) was 92.2 % and 87.0 when compared to the accuracy of CBG which was 79.7 and 72.9 % (ISO 15197: 2003 and 2013, respectively). Bland-Altman plot demonstrated bias and precision of 7.4 +/- A 17.7 mg/dL in acceptable PI group compared to 30.2 +/- A 23.4 mg/dL in low PI group (PI a parts per thousand currency sign 0.3). The CBG test strip must be interpreted carefully in critically ill children. A low PI was associated with poor CBG strip accuracy. WBG test strip from arterial blood was more appropriate for glucose monitoring in children with peripheral hypoperfusion.
机译:葡萄糖试纸在重症监护中的准确性受到质疑。我们调查了危重儿童葡萄糖试纸的准确性。年龄在1个月至18岁之间的小儿重症监护病房。记录人口统计学数据,血液动力学参数和灌注指数(PI)。葡萄糖试纸是从指尖血液[毛细血管血糖(CBG)]和全血[全血葡萄糖(WBG)]以及来自动脉或静脉血样本的实验室血浆血糖(PBG)中进行的。葡萄糖试纸的准确性是根据ISO 15197和Clarke误差网格(CEG)定义的。共获得181个血液样本,包括117个动脉血(CBG,WBG(a),PBG(a))和64个静脉血(CBG,WBG(v),PBG(v))。 WBG(a)的准确性为98.3%和95.2%,而CBG的准确性为(88.7和83.3%。WBG(v)的准确性为92.2%和87.0,而CBG的准确性为79.7和72.9% (分别为ISO 15197:2003和2013。)Bland-Altman图显示可接受的PI组的偏倚和精确度为7.4 +/- A 17.7 mg / dL,而低PI组的偏倚和精度为30.2 +/- A 23.4 mg / dL(PI千分之一货币符号0.3)。危重病儿童必须仔细解释CBG试纸。PI值低与CBG试纸准确性差有关。动脉血WBG试纸更适合于外周血灌注不足儿童的血糖监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号