...
首页> 外文期刊>Journal of cardiovascular magnetic resonance : >Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation.
【24h】

Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation.

机译:使用快速速度编码电影MRI评估冠状动脉血流储备量,以无创检测冠状动脉支架植入后的再狭窄。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Serial change of the coronary flow velocity reserve was evaluated with fast velocity-encoded cine magnetic resonance imaging (MRI) for noninvasive detection of restenosis after coronary stent implantation. METHOD: In total, 60 MRI flow studies were performed in 10 patients with coronary artery disease who undersvent elective successful stent implantation to the lesion in the proximal left anterior descending artery. Flow velocities in the segment that was distal to the stent were measured before and after intravenous injection of dipyridamole. MRI measurements of coronary flow velocity reserve were repeated every 4 weeks for 6 months, and follow-up angiography was performed 6 months after the procedure. RESULTS: In patients without restenosis (n = 7, % diameter stenosis: 27.8%+/-7.1) at follow-up angiography, the coronary flow velocity reserve remained normal during the 6-month follow-up time. The flow velocity reserve was 2.31+/-0.30 at 1 month and 2.52+/-0.25 at 6 months after stent implantation (p = NS). In contrast, the coronary flow velocity reserve showed a significant decrease after 4 months in patients with restenosis (n = 3, % diameter stenosis: 66.3%+/-8.1) at follow-up angiography. The flow velocity reserve was 2.26+/-0.49 at 1 month and 1.52+/-0.09 at 6 months after stent implantation (p < 0.05). CONCLUSION: Fast velocity-encoded cine MRI is a technique that shows promise in providing non-invasive detection of restenosis of coronary stent implantation.
机译:目的:通过快速速度编码电影磁共振成像(MRI)评估冠状动脉血流储备的系列变化,以无创检测冠状动脉支架植入后的再狭窄。方法:总共对10例冠状动脉疾病患者进行了60次MRI流程研究,这些患者未能成功选择将支架成功植入近端左前降支病变中。在静脉注射双嘧达莫之前和之后,测量支架远端部分的流速。每4周重复进行MRI测量冠状动脉血流速度储备,持续6个月,并在术后6个月进行随访血管造影。结果:在随访血管造影中无再狭窄的患者(n = 7,直径狭窄百分比:27.8%+ /-7.1),在6个月的随访时间内冠状动脉流速储备保持正常。支架植入后1个月的流速储备为2.31 +/- 0.30,6个月时的流速储备为2.52 +/- 0.25(p = NS)。相比之下,在再进行血管造影的再狭窄患者(n = 3,%的狭窄百分比:66.3%+ /-8.1)在4个月后,冠状动脉血流储备明显降低。支架植入后1个月的流速储备为2.26 +/- 0.49,6个月时的流速储备为1.52 +/- 0.09(p <0.05)。结论:快速速度电影MRI是一项技术,在为冠状动脉支架植入术的再狭窄提供非侵入性检测方面显示出希望。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号