首页> 外文期刊>Journal of cardiovascular magnetic resonance : >Simultaneous noninvasive measurement of blood flow in the great cardiac vein and left anterior descending artery.
【24h】

Simultaneous noninvasive measurement of blood flow in the great cardiac vein and left anterior descending artery.

机译:同时无创测量心脏大静脉和左前降支动脉的血流。

获取原文
获取原文并翻译 | 示例
           

摘要

Magnetic resonance (MR) flow mapping can be used to quantify flow velocity and volume flow in the coronary vessels noninvasively. The close anatomic relationship of the left anterior descending artery (LAD) with the great cardiac vein (GCV) allows imaging of both in one view. We examined the feasibility to discriminate between these two vessels based on the flow pattern and to measure the flow quantitatively. Eleven individuals with a normal LAD and 8 patients with a diseased LAD underwent MR imaging. From MR angiograms using connectivity to the aortic root, differentiation between the LAD and GCV was obtained. Perpendicular to both vessels, phase-contrast velocity mapping was performed to measure phasic and mean volume flow. After correction for cardiac motion of the vessel, GCV flow was found to be mainly systolic and pointing in the inverse direction as the predominantly diastolic flow in the LAD. These criteria appeared valid in all subjects, even in cases of highly stenotic arteries. The volume flow measurements corrected for body surface area were 31+/-15 ml/min/m2 in the normal LAD (n = 11) and 21+/-10 ml/min/m2 in the diseased LAD (n = 7). The volume flow measurements in the GCV corrected for body surface area were 23+/-19 ml/min/m2 in the normal vessels and 19+/-16 ml/min/m2 in the diseased vessels. In the patient with an occluded LAD and collaterals, the volume flow in the GCV was 7 ml/min/m2. MR is a unique tool for noninvasive simultaneous measurement of the flow pattern and volume flow in the GCV and the LAD, showing a clear distinction between arterial and venous flow.
机译:磁共振(MR)流图可用于无创地量化冠状血管中的流速和体积流量。左前降支动脉(LAD)与心脏大静脉(GCV)的紧密解剖关系允许在一个视图中对两者进行成像。我们检查了基于流量模式区分这两个容器并定量测量流量的可行性。 LAD正常的11个人和LAD病的8例患者接受了MR成像。使用连接到主动脉根部的MR血管造影照片,可确定LAD与GCV之间的区别。垂直于两个血管,进行相衬速度映射以测量相量和平均体积流量。在对血管的心脏运动进行校正后,发现GCV流量主要是收缩期的,并指向反方向,这是LAD中主要的舒张期流量。这些标准在所有受试者中似乎都有效,即使在高度狭窄的动脉中也是如此。校正后的体表面积体积流量在正常LAD(n = 11)中为31 +/- 15 ml / min / m2,在患病LAD(n = 7)中为21 +/- 10 ml / min / m2。经GCV校正后的体表面积的体积流量在正常血管中为23 +/- 19 ml / min / m2,在患病血管中为19 +/- 16 ml / min / m2。在患有LAD闭塞和侧支的患者中,GCV的体积流量为7 ml / min / m2。 MR是用于无创同时测量GCV和LAD中流量模式和体积流量的独特工具,显示了动脉和静脉血流之间的明显区别。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号