...
首页> 外文期刊>Journal of cardiology >Visualization of coronary plaque in type 2 diabetes mellitus patients using a new 40MHz intravascular ultrasound imaging system
【24h】

Visualization of coronary plaque in type 2 diabetes mellitus patients using a new 40MHz intravascular ultrasound imaging system

机译:使用新型40MHz血管内超声成像系统可视化2型糖尿病患者的冠状动脉斑块

获取原文
获取原文并翻译 | 示例

摘要

Background: Previous epidemiological studies demonstrated plaque vulnerability to be high in diabetic patients. iMap-intravascular ultrasound (IVUS) is a recently developed radiofrequency 40. MHz IVUS imaging system for tissue characterization. This study aimed to characterize coronary plaque in target lesions of diabetic patients using iMap-IVUS. Methods: We studied 175 treated vessels in 146 patients with stable angina pectoris and analyzed plaque components of culprit lesions by iMAP-IVUS. Patients were divided into 2 groups: non-diabetic (non-DM: 112 vessels, 93 patients) and diabetic (DM: 63 vessels, 53 patients). Results: In gray-scale IVUS 2D analysis, there were no differences in IVUS parameters. In 3D analysis, the DM group tended to have a larger plaque volume (p=0.07) and plaque burden (p=0.10). At minimum lumen sites, the absolute lipidic and necrotic areas (0.84±0.44mm 2 vs. 0.58±0.41mm 2, p0.001, and 2.42±1.65mm 2 vs. 1.46±1.76mm 2, p0.001, respectively) and percent lipidic and necrotic areas were significantly greater in the DM than in the non-DM group (8.39±3.38% vs. 5.25±2.30%, p0.0001, and 23.65±11.54% vs. 12.99±10.71%, p0.0001, respectively). In addition, the absolute lipidic and necrotic volumes (11.75±10.59mm 3 vs. 8.18±6.24mm 3, p0.01, and 29.99±28.90mm 3 vs. 19.44±19.35mm 3, p0.01, respectively) and percent lipidic and necrotic volumes were significantly greater in the DM than in the non-DM group (6.27±1.92% vs. 5.13±1.82%, p0.0001, and 16.54±7.56% vs. 12.08±6.05%, p0.0001, respectively). Conclusion: Characterization of coronary plaque by iMAP-IVUS in diabetic patients showed increased lipidic amount and necrotic plaque volume relative to subjects without DM.
机译:背景:先前的流行病学研究表明,糖尿病患者的斑块易损性很高。 iMap血管内超声(IVUS)是最近开发的40. MHz射频IVUS成像系统,用于组织表征。这项研究旨在使用iMap-IVUS表征糖尿病患者目标病变的冠状斑块。方法:我们在146例稳定型心绞痛患者中研究了175根经治疗的血管,并通过iMAP-IVUS分析了罪魁祸首的斑块成分。患者分为两组:非糖尿病(非糖尿病:112血管,93例患者)和糖尿病(糖尿病:63血管,53例)。结果:在灰度级IVUS 2D分析中,IVUS参数没有差异。在3D分析中,DM组倾向于具有更大的斑块体积(p = 0.07)和斑块负担(p = 0.10)。在最小管腔部位,绝对脂质和坏死面积(分别为0.84±0.44mm 2与0.58±0.41mm 2,p <0.001和2.42±1.65mm 2与1.46±1.76mm 2,p <0.001)和DM的脂质和坏死面积百分比显着高于非DM组(8.39±3.38%vs.5.25±2.30%,p <0.0001,和23.65±11.54%vs.12.99±10.71%,p <0.0001,分别)。此外,脂质和坏死的绝对体积(分别为11.75±10.59mm 3与8.18±6.24mm 3,p <0.01和29.99±28.90mm 3与19.44±19.35mm 3,p <0.01)和脂质百分比DM的坏死体积显着大于非DM组(分别为6.27±1.92%和5.13±1.82%,p <0.0001,和16.54±7.56%对12.08±6.05%,p <0.0001) 。结论:与没有DM的受试者相比,iMAP-IVUS对糖尿病患者的冠状动脉斑块表征显示脂质量和坏死斑块体积增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号