Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system.

机译:通过聚四氟乙烯片和起搏器系统的导管涂层预防起搏器相关的接触性皮炎。

获取原文
获取原文并翻译 | 示例

摘要

A 73-year-old female with sick sinus syndrome and atrial fibrillation was implanted with a ventricular demand inhibit pacemaker. She subsequently developed multiple episodes of skin irritation and necrosis. Skin patch testing revealed sensitivity to almost every component of the pacemaker system. The pacemaker was removed and replaced with a new pacemaker in which the generator was covered with a polytetrafluoroethylene (PTFE) sheet and the lead was covered with PTFE conduit. The patient suffered no further episodes of pacemaker-associated contact dermatitis.
机译:一名73岁的患有窦病综合征和房颤的女性植入了抑制心室起搏器。随后,她出现了多处皮肤刺激和坏死的发作。皮肤贴剂测试显示了对起搏器系统几乎每个组件的敏感性。拆下起搏器并更换为新的起搏器,在该起搏器中,发生器覆盖有聚四氟乙烯(PTFE)薄板,引线覆盖有PTFE导管。该患者不再发生起搏器相关的接触性皮炎。