...
首页> 外文期刊>Journal of biomedical materials research. Part B, Applied biomaterials. >Ultramorphological Analysis of Resin-Dentin Interfaces Produced with Water-Based Single-Step and Two-Step Adhesives: Nanoleakage Expression
【24h】

Ultramorphological Analysis of Resin-Dentin Interfaces Produced with Water-Based Single-Step and Two-Step Adhesives: Nanoleakage Expression

机译:水性单步和两步胶生产的树脂-牙本质界面的超形态学分析:纳米渗漏表达。

获取原文
获取原文并翻译 | 示例
           

摘要

This study evaluated the nanoleakage patterns in bonded interfaces using two single-step, self-etching adfhesives (Adper Prompt-AD, and One-up Bond F-OB), two two-step, self-etching primers (Clearfil SE Bond-CF, and Unifil Bond-UB), and one two-- step, total-etch adhesive (Single Bond-SB). Dentin surfaces were bonded with the adhesive systems and stored in water at 37 deg C for 1 week and 6 months. After storage periods, teeth were sectioned into 0.8 nun-thick slabs, coated with nail varnish except for the bonded interfaces, and immersed in ammoniacal AgNO_3 for 24 h. After immersion in photodeveloping solution, bonded sections were prepared and observed under a SEM using the backscattered electron mode. Undemineralized, unstained, epoxy resin-embedded sections were prepared for TEM. Nanoleakage patterns were qualitatively compared between periods. Nanoleakage was observed in all bonded specimens at both periods. CF and UB presented silver deposits predominantly restricted to the thin (0.5 mu m) hybrid layer (HL) at both periods. Although no evident differences were observed in the nanoleakage pattern of UB at 7 days and 6 months, CF presented enlarged areas of silver impregnation after 6 months. SB presented accumulation of silver particles mostly within the HL at 7 days, which was intensified after 6 months. AD and OB presented massive silver accumulation within the HL and the overlying adhesive layer. No evident differences were noticed between storage periods. Silver impregnation increased for all adhesive systems from 7 days to 6 months, except for UB.
机译:这项研究使用两种单步自蚀刻胶粘剂(Adper Prompt-AD和One-up Bond F-OB),两种两步自蚀刻底漆(Clearfil SE Bond-CF)评估了键合界面中的纳米泄漏模式,Unifil Bond-UB)和两步全蚀刻胶(Single Bond-SB)。牙本质表面通过粘合剂体系粘合,并在37摄氏度的水中储存1周和6个月。储存一段时间后,将牙齿切成0.8微米厚的平板,除粘结界面外用指甲油覆盖,然后浸入氨水AgNO_3中24小时。浸入显影液中后,制备结合部分,并在SEM下使用背散射电子模式对其进行观察。准备用于TEM的未脱矿化,未染色的环氧树脂包埋切片。定性比较各时期之间的纳米泄漏模式。在这两个时期,在所有粘结的样品中均观察到了纳米泄漏。 CF和UB在这两个时期都主要沉积在薄的混合层(0.5μm)内,形成了银沉积层。尽管在7天和6个月时UB的纳米泄漏模式没有观察到明显差异,但CF在6个月后呈现出更大的浸银面积。 SB在第7天出现了大部分在HL内的银颗粒积聚,在6个月后加剧了。 AD和OB在HL及其上层的粘合剂层中出现大量的银堆积。储存期之间未发现明显差异。除UB外,所有胶粘剂体系的银浸渍从7天增加到6个月。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号