...
首页> 外文期刊>Journal of Biomechanics >Variation of trabecular architecture in proximal femur of postmenopausal women.
【24h】

Variation of trabecular architecture in proximal femur of postmenopausal women.

机译:绝经后女性股骨近端骨小梁结构的变化。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This investigation of microstructure in the human proximal femur probes the relationship between the parameters of the FRAX index of fracture risk and the parameters of bone microstructure. The specificity of fracture sites at the proximal femur raises the question of whether trabecular parameters are site-specific during post-menopause, before occurrence of fragility fracture. The donated proximal femurs of sixteen post-menopausal women in the sixth and seventh decades of life, free of metabolic pathologies and therapeutic interventions that could have altered the bone tissue, constituted the material of the study. We assessed bone mineral density of the proximal femurs by dual energy X-ray absorptiometry and then sectioned the femurs through the center of the femoral head and along the femoral neck axis. For each proximal femur, morphometry of trabeculae was conducted on the plane of the section divided into conventional regions and sub-regions consistent with the previously identified trabecular families that provide regions of relatively homogeneous microstructure. Mean trabecular width and percent bone area were calculated at such sites. Our findings indicate that each of mean trabecular width and percent bone area vary within each proximal femur independently from each other, with dependence on site. Both trabecular parameters show significant differences between pairs of sites. We speculate that a high FRAX index at the hip corresponds to a reduced percent bone area among sites that gives a more homogeneous and less site-specific quality to the proximal femur. This phenomenon may render the local tissue less able to carry out the expected mechanical function.
机译:这项对人类近端股骨微结构的研究探究了骨折风险的FRAX指数参数与骨微结构参数之间的关系。股骨近端骨折部位的特异性提出了以下问题:在绝经后,易碎性骨折发生之前,骨小梁参数是否是部位特异性的。这项研究的内容是,在生命的第六和第七个十年中,有十六名绝经后妇女捐赠的近端股骨,没有代谢病理学和可能改变骨组织的治疗性干预措施。我们通过双能X射线吸收法评估了股骨近端的骨矿物质密度,然后将股骨切开穿过股骨头的中心并沿股骨颈轴。对于每个近端股骨,在截面的平面上进行小梁的形态测量,该截面分为常规区域和与先前确定的小梁家族一致的子区域,小梁家族提供相对均匀的微结构区域。在这些部位计算平均小梁宽度和骨面积百分比。我们的研究结果表明,每个小梁的平均宽度和骨面积百分比在每个股骨近端内彼此独立,并取决于部位。两种小梁参数在位点对之间显示出显着差异。我们推测,髋部较高的FRAX指数对应于各部位之间骨面积的减少,从而使股骨近端的骨质更加均匀且部位特异性较低。这种现象可能使局部组织不能执行预期的机械功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号