首页> 外文期刊>Journal of Biomechanics >Strain and elongation of the human gastrocnemius tendon and aponeurosis during maximal plantarflexion effort
【24h】

Strain and elongation of the human gastrocnemius tendon and aponeurosis during maximal plantarflexion effort

机译:足底屈伸最大时人腓肠肌腱和腱膜的应变和伸长

获取原文
获取原文并翻译 | 示例
           

摘要

Regarding the strain and elongation distribution along the tendon and aponeurosis the literature is reporting different findings. Therefore, the purpose of this study was to examine in vivo the elongation and the strain of the human gastrocnemius medialis tendon and aponeurosis simultaneously at the same trial during maximal voluntary plantarflexion efforts. Twelve subjects participated in the study. The subjects performed isometric maximal voluntary contractions of their left leg on a Biodex-dynamometer. The kinematics of the leg were recorded using the Vicon 624 system with 8 cameras operating at 120 Hz. Two ultrasound probes were used to visualise the tendon (myotendinous junction region) and the distal aponeurosis of the gastrocnemius medialis respectively. The main findings were: (a) the absolute elongation of the gastrocnemius medialis tendon was different to that of the aponeurosis, (b) the strain of the gastrocnemius medialis tendon did not differ from the strain of the aponeurosis, (c) during the "isometric" plantarflexion the ankle angle exhibited significant changes, and (d) the non-rigidity of the dynamometer arm-foot system and the coactivity of the tibialis anterior both have a significant influence on the moment exerted at the ankle joint. Thus the strain of the human gastrocnemius medialis tendon and aponeurosis estimated in vivo using two-dimensional ultrasonography is uniform. To calculate the elongation of the whole tendon it is necessary to multiply the strain calculated for the examined part of the tendon by the total length of the tendon. (c) 2004 Elsevier Ltd. All rights reserved.
机译:关于沿肌腱和腱膜的应变和伸长分布,文献报道了不同的​​发现。因此,本研究的目的是在最大自愿性plant屈努力的同一试验中同时检查体内腓肠肌腱和腱膜的伸长率和应变。十二名受试者参加了该研究。受试者在Biodex测力计上进行了左腿等距的最大自愿收缩。使用Vicon 624系统记录了腿部的运动学,该系统具有8个以120 Hz运行的摄像机。使用两个超声探头分别显示腓肠肌内侧的肌腱(肌腱连接区)和远端腱膜。主要发现是:(a)腓肠肌内侧肌腱的绝对伸长不同于腱膜的伸长,(b)腓肠肌内侧肌腱的应变与腱膜的伸长率没有差异,(c)在“等距”足底屈曲,踝角显示出显着变化,并且(d)测力计臂-足系统的非刚性和胫骨前肌的共同活动性都对施加在踝关节上的力矩有重要影响。因此,使用二维超声在体内估计的人腓肠肌内侧肌腱和腱膜的应变是均匀的。为了计算整个肌腱的伸长率,必须将针对肌腱检查部分计算出的应变乘以肌腱的总长度。 (c)2004 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号