首页> 外文期刊>Journal of Biomechanics >Correlations between mean echogenicity and material properties of normal and diseased equine superficial digital flexor tendons: an in vitro segmental approach
【24h】

Correlations between mean echogenicity and material properties of normal and diseased equine superficial digital flexor tendons: an in vitro segmental approach

机译:正常和患病马表浅指屈肌腱的平均回声与材料特性之间的相关性:体外分段方法

获取原文
获取原文并翻译 | 示例
       

摘要

The objective of this study was to test the hypothesis that tendon echogenicity is associated with the material properties of the corresponding tendon site, especially in case of lesions, due to local changes in tendon matrix composition. Four normal and nine spontaneously injured equine superficial digital flexor tendons (SDFT) were isolated then ultrasonographically examined under tension, in a special device placed in a water bath. Ultrasonographic transversal images (7.5 MHz linear transducer) of five segments along each tendon were digitized, and analyzed in order to measure the mean cross-sectional area (MCSA) and mean echogenicity (ME) of each segment. The tendons were then tested in traction until rupture in a testing machine. For each segment, stress and strain were determined throughout the test, and the elastic modulus (EM) was evaluated. The tendon lesions were also documented by histology.No correlation was found between ME and the material properties of normal tendon segments. At the rupture sites of the nine diseased tendons, ME was positively correlated with maximal stress and EM, whereas no correlation was demonstrated with maximal strain. Besides, a positive correlation was demonstrated between ME and both MCSA and EM, when the three metacarpal segments of the diseased tendons were considered.Although ME gives only rough information about tendon matrix structure, it does show, under these in vitro conditions, significant correlations with material properties of pathological tendon segments, which may improve the functional significance and therefore the pronostic value of the ultrasonographic examination of tendon lesions. (c) 2004 Elsevier Ltd. All rights reserved.
机译:这项研究的目的是检验以下假设:腱回声性与相应腱部位的材料特性有关,尤其是在病变情况下,由于腱基质成分的局部变化。分离出四个正常的和九个自发受伤的马浅指屈肌腱(SDFT),然后在置于水浴中的特殊装置中,在张力下进行超声检查。将沿每个肌腱的五个节段的超声横断面图像(7.5 MHz线性换能器)数字化并进行分析,以测量每个节段的平均横截面积(MCSA)和平均回声(ME)。然后对肌腱进行牵引测试,直到在测试机中断裂。对于每个部分,在整个测试过程中确定应力和应变,并评估弹性模量(EM)。组织学也记录了肌腱病变。ME与正常肌腱节段的材料特性之间没有相关性。在9个患病肌腱的断裂部位,ME与最大应力和EM正相关,而与最大应变无相关性。此外,当考虑患病肌腱的三个掌骨节段时,ME与MCSA和EM之间呈正相关关系。尽管ME仅提供有关肌腱基质结构的粗略信息,但它确实显示了在这些体外条件下的显着相关性具有病理性肌腱节段的材料特性,可以改善功能性意义,并因此改善肌腱病变超声检查的预言价值。 (c)2004 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号