Background: Alumina ceramic-on-ceramic bearings have gained popularity in hip arthroplasty because of their properties of low wear and chemical inertness. In a previous study, we reported the excellent clinical results in a series of cementless ceramic-on-ceramic primary total hip arthroplasties at a minimum of five years of follow-up. The purpose of the present study was to determine the results in the same patient cohort at a minimum of ten years of follow-up. Methods: A series of 301 consecutive primary cementless total hip arthroplasties was assessed clinically and radiographically. Clinical information was available for 244 hips in 227 surviving patients at a minimum of ten years of followup, and radiographic information was available for 184 hips in 172 patients. Results: Twenty-six (9.2%) of the patients had died of an unrelated cause and eight (2.7%) had undergone revision arthroplasty by the time of the latest follow-up. The average Harris hip score was 94 points, with 95% (232) of the patients having an excellent or good result and <4% (nine) having moderate residual pain. All radiographic assessments showed evidence of stable osseous ingrowth. Nine revisions had been performed, including four femoral component revisions due to periprosthetic fracture, one femoral revision due to aseptic loosening, one femoral revision secondary to a femoral shortening osteotomy for nerve palsy, two acetabular cup revisions due to psoas tendinitis, and a repeat revision in one of the patients with psoas tendinitis due to acetabular osteolysis. The overall survival rate of the implants was 98% (95% confidence interval, 94.2% to 99.6%) at ten years with revision for any reason as the end point. Conclusions: The patients in our series had a good implant survival rate, good function, a low implant wear rate as reported in the previous study, and no further radiographic evidence of failure at ten years after cementless primary total hip arthroplasty with alumina ceramic-on-ceramic bearings. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
机译:背景:氧化铝陶瓷陶瓷轴承因其低磨损和化学惰性的特性而在髋关节置换术中广受欢迎。在先前的研究中,我们报告了至少五年的随访中一系列非骨水泥陶瓷上陶瓷原位全髋关节置换术的出色临床结果。本研究的目的是在至少十年的随访中确定同一患者队列的结果。方法:对301例连续的原发性非骨水泥型全髋关节置换术进行了临床和影像学评估。在至少十年的随访中,可获得227例幸存患者的244髋的临床信息,而172例患者的184髋的影像学信息可获取。结果:截至最近一次随访,有26例(9.2%)患者死于无关原因,而8例(2.7%)接受了翻修置换术。哈里斯的平均髋关节得分为94分,其中95%(232)的患者具有优异或良好的治疗效果,<4%(9)的患者具有中度残余疼痛。所有放射学评估均显示骨长入稳定的证据。进行了九次翻修,包括由于假体周围骨折导致的四次股骨成分翻修,由于无菌性松动而引起的一股股骨翻修,因神经性麻痹而进行股骨缩短截骨术继发的一例股骨翻修,因腰肌腱炎引起的两例髋臼杯翻修和一次复查在一名因髋臼骨溶解引起的腰肌腱炎患者中。植入物的十年总生存率为98%(置信区间为95%,从94.2%到99.6%),无论出于何种原因进行翻修都是如此。结论:我们系列中的患者具有如先前研究中所报道的良好的植入物存活率,良好的功能,较低的植入物磨损率,并且在无骨水泥全髋关节置换术加氧化铝陶瓷的情况下,十年后没有进一步的放射影像学证据证实失败-陶瓷轴承。证据级别:治疗级别IV。有关证据水平的完整说明,请参见《作者说明》。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号